» Articles » PMID: 25405605

Stimuli-responsive Reagent System for Enabling Microfluidic Immunoassays with Biomarker Purification and Enrichment

Overview
Journal Bioconjug Chem
Specialty Biochemistry
Date 2014 Nov 19
PMID 25405605
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Immunoassays have been translated into microfluidic device formats, but significant challenges relating to upstream sample processing still limit their applications. Here, stimuli-responsive polymer-antibody conjugates are utilized in a microfluidic immunoassay to enable rapid biomarker purification and enrichment as well as sensitive detection. The conjugates were constructed by covalently grafting poly(N-isopropylacrylamide) (PNIPAAm), a thermally responsive polymer, to the lysine residues of anti-prostate specific antigen (PSA) Immunoglobulin G (IgG) using carbodiimide chemistry via the polymer end-carboxylate. The antibody-PNIPAAm (capture) conjugates and antibody-alkaline phosphatase (detection) conjugates formed sandwich immunocomplexes via PSA binding in 50% human plasma. The complexes were loaded into a recirculating poly(dimethylsiloxane) microreactor, equipped with micropumps and transverse flow features, for subsequent separation, enrichment, and quantification. The immunocomplexes were captured by heating the solution to 39 °C, mixed over the transverse features for 2 min, and washed with warm buffer. In one approach, the assay utilized immunocomplex solution that was contained in an 80 nL microreactor, which was loaded with solution at room temperature and subsequently heated to 39 °C. The assay took 25 min and resulted in 37 pM PSA limit of detection (LOD), which is comparable to a plate ELISA employing the same antibody pair. In another approach, the microreactor was preheated to 39 °C, and immunocomplex solution was flowed through the reactor, mixed, and washed. When the specimen volume was increased to 7.5 μL by repeating the capture process three times, the higher specimen volume led to immunocomplex enrichment within the microreactor. The resulting assay LOD was 0.5 pM, which is 2 orders of magnitude lower than the plate ELISA. Both approaches generate antigen specific signal over a clinically significant range. The sample processing capabilities and subsequent utility in a biomarker assay demonstrate the opportunity for stimuli-responsive polymer-protein conjugates in novel diagnostic technologies.

Citing Articles

Physicochemical Stimulus-Responsive Systems Targeted with Antibody Derivatives.

Mohammadi R, Ghani S, Arezumand R, Farhadi S, Khazaee-Poul Y, Kazemi B Curr Mol Med. 2023; 24(10):1250-1268.

PMID: 37594115 DOI: 10.2174/1566524023666230818093016.


Thermoresponsive bio-affinity interfaces for temperature-modulated selective capture and release of targeted exosomes.

Nagase K, Yamazaki K, Maekawa Y, Kanazawa H Mater Today Bio. 2023; 18:100521.

PMID: 36590982 PMC: 9800632. DOI: 10.1016/j.mtbio.2022.100521.


Antibody drug separation using thermoresponsive anionic polymer brush modified beads with optimised electrostatic and hydrophobic interactions.

Nagase K, Ishii S, Ikeda K, Yamada S, Ichikawa D, Akimoto A Sci Rep. 2020; 10(1):11896.

PMID: 32719404 PMC: 7385495. DOI: 10.1038/s41598-020-68707-7.


Human Immunodeficiency Virus (HIV) Separation and Enrichment via the Combination of Antiviral Lectin Recognition and a Thermoresponsive Reagent System.

Phan J, Nehilla B, Srinivasan S, Coombs R, Woodrow K, Lai J Pharm Res. 2016; 33(10):2411-20.

PMID: 27401412 DOI: 10.1007/s11095-016-1980-7.


Cobalt-Porphyrin-Platinum-Functionalized Reduced Graphene Oxide Hybrid Nanostructures: A Novel Peroxidase Mimetic System For Improved Electrochemical Immunoassay.

Shu J, Qiu Z, Wei Q, Zhuang J, Tang D Sci Rep. 2015; 5:15113.

PMID: 26462136 PMC: 4602201. DOI: 10.1038/srep15113.


References
1.
Schuck P . Kinetics of ligand binding to receptor immobilized in a polymer matrix, as detected with an evanescent wave biosensor. I. A computer simulation of the influence of mass transport. Biophys J. 1996; 70(3):1230-49. PMC: 1225050. DOI: 10.1016/S0006-3495(96)79681-9. View

2.
Sebra R, Masters K, Cheung C, Bowman C, Anseth K . Detection of antigens in biologically complex fluids with photografted whole antibodies. Anal Chem. 2006; 78(9):3144-51. DOI: 10.1021/ac052246y. View

3.
Peoples M, Karnes H . Microfluidic immunoaffinity separations for bioanalysis. J Chromatogr B Analyt Technol Biomed Life Sci. 2007; 866(1-2):14-25. DOI: 10.1016/j.jchromb.2007.08.030. View

4.
Sebra R, Masters K, Bowman C, Anseth K . Surface grafted antibodies: controlled architecture permits enhanced antigen detection. Langmuir. 2005; 21(24):10907-11. DOI: 10.1021/la052101m. View

5.
Morris D, Dillon P, Very D, Ng P, KISH L, Goldblatt J . Bayer Immuno 1 PSA Assay: an automated, ultrasensitive method to quantitate total PSA in serum. J Clin Lab Anal. 1998; 12(1):65-74. PMC: 6807852. View