» Articles » PMID: 25370153

Accelerometer-based Measures in Physical Activity Surveillance: Current Practices and Issues

Overview
Journal Br J Sports Med
Specialty Orthopedics
Date 2014 Nov 6
PMID 25370153
Citations 138
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Self-reports of physical activity (PA) have been the mainstay of measurement in most non-communicable disease (NCD) surveillance systems. To these, other measures are added to summate to a comprehensive PA surveillance system. Recently, some national NCD surveillance systems have started using accelerometers as a measure of PA. The purpose of this paper was specifically to appraise the suitability and role of accelerometers for population-level PA surveillance.

Methods: A thorough literature search was conducted to examine aspects of the generalisability, reliability, validity, comprehensiveness and between-study comparability of accelerometer estimates, and to gauge the simplicity, cost-effectiveness, adaptability and sustainability of their use in NCD surveillance.

Conclusions: Accelerometer data collected in PA surveillance systems may not provide estimates that are generalisable to the target population. Accelerometer-based estimates have adequate reliability for PA surveillance, but there are still several issues associated with their validity. Accelerometer-based prevalence estimates are largely dependent on the investigators' choice of intensity cut-off points. Maintaining standardised accelerometer data collections in long-term PA surveillance systems is difficult, which may cause discontinuity in time-trend data. The use of accelerometers does not necessarily produce useful between-study and international comparisons due to lack of standardisation of data collection and processing methods. To conclude, it appears that accelerometers still have limitations regarding generalisability, validity, comprehensiveness, simplicity, affordability, adaptability, between-study comparability and sustainability. Therefore, given the current evidence, it seems that the widespread adoption of accelerometers specifically for large-scale PA surveillance systems may be premature.

Citing Articles

Methodological Choices on 24-h Movement Behavior Assessment by Accelerometry: A Scoping Review.

Rodrigues B, Videira-Silva A, Lopes L, Sousa-Sa E, Vale S, Cliff D Sports Med Open. 2025; 11(1):25.

PMID: 40080301 PMC: 11906950. DOI: 10.1186/s40798-025-00820-1.


Relationship between accelerometer-measured physical activity and depressive symptoms in hemodialysis patients with comorbid diabetes mellitus: a multicenter cross-sectional study.

Liang R, Chen X, Siqin G, Zhang Z, Zhang S, Li L Front Psychol. 2025; 16:1478765.

PMID: 39958771 PMC: 11825451. DOI: 10.3389/fpsyg.2025.1478765.


Using Free-Living Heart Rate Data as an Objective Method to Assess Physical Activity: A Scoping Review and Recommendations by the INTERLIVE-Network Targeting Consumer Wearables.

Schumann M, Feuerbacher J, Heinrich L, Olvera-Rojas M, Sclafani A, Brond J Sports Med. 2025; .

PMID: 39893599 DOI: 10.1007/s40279-024-02159-1.


Nation-wide cohort of device-measured sedentary time and physical activity in the USA-the Cancer Prevention Study-3 (CPS-3) Accelerometry Substudy: cohort profile.

Rees-Punia E, Nelson J, Briggs P, Joiner N, Hodge J, Bontemps-Jones J BMJ Open. 2025; 15(1):e085896.

PMID: 39809559 PMC: 11751977. DOI: 10.1136/bmjopen-2024-085896.


A cross-sectional study of physical activity and chronic diseases among middle-aged and elderly in China.

Huang Y, Lu Z Sci Rep. 2024; 14(1):30701.

PMID: 39730392 PMC: 11680886. DOI: 10.1038/s41598-024-78360-z.