Abstract

Increasingly, smartphones are used as portable personal computers, revolutionizing communication styles and entire lifestyles. Using 3D-printing technology we have made a disposable minicartridge that can be easily prototyped to turn any kind of smartphone or tablet into a portable luminometer to detect chemiluminescence derived from enzyme-coupled reactions. As proof-of-principle, lactate oxidase was coupled with horseradish peroxidase for lactate determination in oral fluid and sweat. Lactate can be quantified in less than five minutes with detection limits of 0.5 mmol L(-1) (corresponding to 4.5 mg dL(-1)) and 0.1 mmol L(-1) (corresponding to 0.9 mg dL(-1)) in oral fluid and sweat, respectively. A smartphone-based device shows adequate analytical performance to offer a cost-effective alternative for non-invasive lactate measurement. It could be used to evaluate lactate variation in relation to the anaerobic threshold in endurance sport and for monitoring lactic acidosis in critical-care patients.

Citing Articles

Deep Learning-Assisted Smartphone-Based Electrochemiluminescence Visual Monitoring Biosensor: A Fully Integrated Portable Platform.

Bhaiyya M, Rewatkar P, Pimpalkar A, Jain D, Srivastava S, Zalke J Micromachines (Basel). 2024; 15(8).

PMID: 39203710 PMC: 11356000. DOI: 10.3390/mi15081059.


A new colorimetric lactate biosensor based on CUPRAC reagent using binary enzyme (lactate-pyruvate oxidases)-immobilized silanized magnetite nanoparticles.

Ayaz S, Ersan T, Dilgin Y, Apak R Mikrochim Acta. 2024; 191(8):455.

PMID: 38980437 PMC: 11233342. DOI: 10.1007/s00604-024-06531-w.


Enhanced Interstitial Fluid Extraction and Rapid Analysis via Vacuum Tube-Integrated Microneedle Array Device.

Xie Y, He J, He W, Iftikhar T, Zhang C, Su L Adv Sci (Weinh). 2024; 11(21):e2308716.

PMID: 38502884 PMC: 11151006. DOI: 10.1002/advs.202308716.


Advancing 3D printed microfluidics with computational methods for sweat analysis.

Ece E, Olmez K, Haciosmanoglu N, Atabay M, Inci F Mikrochim Acta. 2024; 191(3):162.

PMID: 38411762 PMC: 10899357. DOI: 10.1007/s00604-024-06231-5.


Microfluidic-Based Non-Invasive Wearable Biosensors for Real-Time Monitoring of Sweat Biomarkers.

Shariati Pour S, Calabria D, Emamiamin A, Lazzarini E, Pace A, Guardigli M Biosensors (Basel). 2024; 14(1).

PMID: 38248406 PMC: 10813635. DOI: 10.3390/bios14010029.