Abstract

Purpose: Prosthetic joint infection (PJI) is a devastating complication of total joint arthroplasty. No single laboratory test has perfect sensitivity and specificity; however, culture of periprosthetic tissue is the standard method for PJI diagnosis. Interpretation of positive culture results in PJI diagnostics can be difficult due to the possibility of contamination with microorganisms originating from skin micro flora. Criteria have been established to aid in distinguishing pathogen from contaminant for culture results. A similar criterion has not however been established for polymerase chain reaction (PCR) analysis, which is in part responsible for confusion about the reliability of PCR for PJI diagnostics. The aim of our study was to establish a criterion for interpretation of broad range (BR) PCR results in PJI diagnostics.

Methods: Samples of periprosthetic tissue were retrieved from 100 patients with joint prosthesis failure and analysed with BR-PCR. The results of BR-PCR were evaluated based on the number of samples of periprosthetic tissue with the same bacterial species.

Results: The sensitivity (87.5%) of BR-PCR was highest if the same species was present in at least one sample, although this criterion also resulted in the lowest specificity (92.1%). The sensitivity decreased (83.2%), although without a statistically significant difference, if the same species was present in two or more samples but, at the same time, specificity increased (100%), with a statistically significant difference.

Conclusions: For diagnostics of PJI with BR-PCR the criterion of the same bacterial species in at least two specimens of periprosthetic tissue from the same patient should be used for interpretation of positive results.

Citing Articles

Propidium monoazide-polymerase chain reaction for detection of residual periprosthetic joint infection in two-stage revision.

Askar M, Sajid M, Nassif Y, Ashraf W, Scammell B, Bayston R Mol Biol Rep. 2019; 46(6):6463-6470.

PMID: 31587184 PMC: 11358260. DOI: 10.1007/s11033-019-05092-z.


Detection of bacteria with molecular methods in prosthetic joint infection: sonication fluid better than periprosthetic tissue.

Rak M, KavcIc M, Trebse R, Cor A Acta Orthop. 2016; 87(4):339-45.

PMID: 27123818 PMC: 4967274. DOI: 10.3109/17453674.2016.1165558.

References
1.
Friedrich M, Randau T, Wimmer M, Reichert B, Kuberra D, Stoffel-Wagner B . Lipopolysaccharide-binding protein: a valuable biomarker in the differentiation between periprosthetic joint infection and aseptic loosening?. Int Orthop. 2014; 38(10):2201-7. DOI: 10.1007/s00264-014-2351-9. View

2.
Panousis K, Grigoris P, Butcher I, Rana B, Reilly J, Hamblen D . Poor predictive value of broad-range PCR for the detection of arthroplasty infection in 92 cases. Acta Orthop. 2005; 76(3):341-6. View

3.
Holinka J, Krepler P, Matzner M, Grohs J . Stabilising effect of dynamic interspinous spacers in degenerative low-grade lumbar instability. Int Orthop. 2010; 35(3):395-400. PMC: 3047654. DOI: 10.1007/s00264-010-1017-5. View

4.
Muller M, Morawietz L, Hasart O, Strube P, Perka C, Tohtz S . Diagnosis of periprosthetic infection following total hip arthroplasty--evaluation of the diagnostic values of pre- and intraoperative parameters and the associated strategy to preoperatively select patients with a high probability of joint infection. J Orthop Surg Res. 2008; 3:31. PMC: 2492844. DOI: 10.1186/1749-799X-3-31. View

5.
Achermann Y, Vogt M, Leunig M, Wust J, Trampuz A . Improved diagnosis of periprosthetic joint infection by multiplex PCR of sonication fluid from removed implants. J Clin Microbiol. 2010; 48(4):1208-14. PMC: 2849575. DOI: 10.1128/JCM.00006-10. View