Higher Contact-force Values Associated with Better Mid-term Outcome of Paroxysmal Atrial Fibrillation Ablation Using the SmartTouch™ Catheter

Overview
Journal Europace
Date 2014 Oct 5
PMID 25280910
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

Aims: Real-time measurement of contact force (CF) during catheter ablation of atrial fibrillation (AF) has been recently suggested to potentially impact procedural outcome. However, the role of CF intensity on mid-term results using the SmartTouch™ catheter has not been investigated so far.

Methods And Results: Pulmonary vein isolation (PVI) using the SmartTouch™ catheter was performed in 100 eligible patients (age 62 ± 8; 79% men) undergoing a first procedure of paroxysmal AF catheter ablation. Continuous CF monitoring during catheter ablation allowed calculation of mean CF per patient. Patients were dichotomized into high CF (≥22 g, upper quartile) and low CF (<22 g, remaining) and enroled in a standardized follow-up programme (after a 3-month blanking period), free from antiarrhythmic therapy, with regular evaluations including 24 h Holter recordings at 1, 3, 6, 9, 12, 18, and 24 months. Atrial fibrillation relapse was defined as any symptomatic or asymptomatic atrial arrhythmia lasting >30 s. The average CF among all procedures was 19.6 ± 3.7 g. Though complete PVI was eventually achieved in all cases in both groups, success using an exclusively anatomical approach was higher in the high CF group (92.0 vs. 72.0%; P = 0.04). During a mean follow-up of 19 ± 5 months, a lower incidence of AF relapse was observed in higher CF patients (4.0 vs. 20.0%; log rank P = 0.04). Pericardial tamponade occurred in one patient in the higher CF group. No thromboembolism or procedure-associated deaths were observed.

Conclusion: Higher values of CF overall during antral PVI appear to be associated with a higher likelihood of sinus rhythm maintenance without significantly increasing the complication rate.

Citing Articles

Deep neuromuscular blockade during radiofrequency catheter ablation under general anesthesia reduces the prevalence of atrial fibrillation recurrence when compared to moderate neuromuscular blockade: A randomized controlled trial.

Oh E, Shim J, Jeon S, Cho E, Lee S, Jeong T PLoS One. 2025; 20(1):e0302952.

PMID: 39836668 PMC: 11750084. DOI: 10.1371/journal.pone.0302952.


Long-term results of ablation index guided atrial fibrillation ablation: insights after 5+ years of follow-up from the MPH AF Ablation Registry.

Fitzpatrick N, Herczeg S, Hong K, Seaver F, Rosalejos L, Boles U Front Cardiovasc Med. 2024; 10:1332868.

PMID: 38292455 PMC: 10825003. DOI: 10.3389/fcvm.2023.1332868.


Optimal interlesion distance for 90 and 50 watt radiofrequency applications with low ablation index values: experimental findings in a chronic ovine model.

Bortone A, Ramirez F, Constantin M, Bortone C, Hebert C, Constantin J Europace. 2023; 25(11).

PMID: 37851513 PMC: 10629717. DOI: 10.1093/europace/euad310.


Comparison of lesion characteristics between conventional and high-power short-duration ablation using contact force-sensing catheter in patients with paroxysmal atrial fibrillation.

Chen C, Lee P, Van Ba V, Chuang C, Lin Y, Lo L BMC Cardiovasc Disord. 2021; 21(1):387.

PMID: 34372779 PMC: 8353766. DOI: 10.1186/s12872-021-02196-y.


Size matters in atrial fibrillation: the underestimated importance of reduction of contiguous electrical mass underlying the effectiveness of catheter ablation.

Hartley A, Shalhoub J, Ng F, Krahn A, Laksman Z, Andrade J Europace. 2021; 23(11):1698-1707.

PMID: 33948648 PMC: 8576280. DOI: 10.1093/europace/euab078.