The Accuracy and Reliability of Pre-operative Templating in Revision Total Knee Arthroplasty. A Comparison of Analogue and Digital Methods
Overview
Authors
Affiliations
Aims: To determine whether the size of the prostheses used in revision knee arthroplasty may be accurately and reproducibly predicted using analogue or digital pre-operative templating techniques.
Methods: Pre-operative radiographs were templated using analogue radiographs and acetate templates, digital radiographs and acetate templates and digital radiographs and digital templating software.
Results: Overall accuracy of predicting the size of implant used at surgery was 44%. There was no significant difference in the accuracy of the various templating techniques (p = 0.098).
Conclusions: Templating in revision knee arthroplasty is neither of suitable accuracy nor reliability enough to safely recommend its use for implant size prediction.
Park K, Kim M, Yoon D, Jeon Y J Orthop Surg Res. 2024; 19(1):637.
PMID: 39380122 PMC: 11463000. DOI: 10.1186/s13018-024-05128-6.
Balato G, De Matteo V, Guarino A, De Mauro D, Baldi D, Cavaliere C Jt Dis Relat Surg. 2024; 35(3):473-482.
PMID: 39189555 PMC: 11411891. DOI: 10.52312/jdrs.2024.1591.
Digital templating of rotating hinge revision and primary total knee arthroplasty.
Savov P, Windhagen H, Haasper C, Ettinger M Orthop Rev (Pavia). 2019; 10(4):7811.
PMID: 30662687 PMC: 6315305. DOI: 10.4081/or.2018.7811.