To measure volume blood flow quantitatively in human abdominal arteries, we used an ultrasonic image-directed Doppler system and electromagnetic flowmeter to first measure volume flow in canine arteries. In dogs, there was a strong linear correlation (R = 0.98) between the product of the time average of the maximum blood flow velocity and the average cross-sectional area and the volume blood flow measured by an electromagnetic flowmeter. These results enabled measurement of volume blood flow in the human superior mesenteric (SMA), splenic (SPA), and common hepatic (CHA) arteries from the abdominal wall. Comparison of pulsatility index values indicated a larger vascular resistance in the SMA than in the SPA or CHA.

Citing Articles

Daikenchuto increases blood flow in the superior mesenteric artery in humans: A comparison study between four-dimensional phase-contrast vastly undersampled isotropic projection reconstruction magnetic resonance imaging and Doppler ultrasound.

Suzuki K, Takehara Y, Sakata M, Kawate M, Ohishi N, Sugiyama K PLoS One. 2021; 16(1):e0245878.

PMID: 33503053 PMC: 7840032. DOI: 10.1371/journal.pone.0245878.


A technique for intra-procedural blood velocity quantitation using time-resolved 2D digital subtraction angiography.

Hoffman C, Periyasamy S, Longhurst C, Medero R, Roldan-Alzate A, Speidel M CVIR Endovasc. 2021; 4(1):11.

PMID: 33411087 PMC: 7790988. DOI: 10.1186/s42155-020-00199-y.


Repository Describing an Aging Population to Inform Physiologically Based Pharmacokinetic Models Considering Anatomical, Physiological, and Biological Age-Dependent Changes.

Stader F, Siccardi M, Battegay M, Kinvig H, Penny M, Marzolini C Clin Pharmacokinet. 2018; 58(4):483-501.

PMID: 30128967 DOI: 10.1007/s40262-018-0709-7.


Intraobserver reproducibility and interobserver agreement of ultrasonic flowmetry using the velocity profile color doppler method in the common carotid artery.

Taniguchi N, Takano R, Itoh K, Kaneko S, Onoguchi A, Wang Y J Med Ultrason (2001). 2016; 30(1):3-11.

PMID: 27285149 DOI: 10.1007/BF02485164.


Transabdominal ultrasonography of the small bowel.

Kralik R, Trnovsky P, Kopacova M Gastroenterol Res Pract. 2013; 2013:896704.

PMID: 24348544 PMC: 3852808. DOI: 10.1155/2013/896704.