» Articles » PMID: 25199441

Short-term Corneal Changes with Gas-permeable Contact Lens Wear in Keratoconus Subjects: a Comparison of Two Fitting Approaches

Overview
Journal J Optom
Specialty Ophthalmology
Date 2014 Sep 10
PMID 25199441
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches.

Methods: Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-point-touch fitting approach. The lens' back optic zone radius (BOZR) was 0.4mm and 0.1mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared.

Results: A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p<0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p<0.05). Significant reduction was found over time in CCA (p=0.001) and anterior corneal asphericity in both groups (p<0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p<0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p<0.05).

Conclusion: Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apical-touch was associated with greater corneal flattening in comparison to three-point-touch lens wear.

Citing Articles

Longitudinal assessment of the progression of severe keratoconus based on corneal topography.

Yang X, Wang Y, Liu Y, Lyu Y, Wang W Sci Rep. 2024; 14(1):19642.

PMID: 39179596 PMC: 11344030. DOI: 10.1038/s41598-024-70084-4.


Investigation of contrast visual acuity with rigid gas permeable contact lenses after penetrating Keratoplasty.

Zhang J, Lin X, Wang X, Cheng Z, Li X, He J BMC Ophthalmol. 2023; 23(1):12.

PMID: 36624403 PMC: 9830785. DOI: 10.1186/s12886-023-02769-9.


Impact of rigid gas-permeable contact lens on keratometric indices and corneal thickness of keratoconus eyes examined with anterior segment optical coherence tomography.

Akiyama K, Ono T, Ishii H, Chen L, Kitamoto K, Toyono T PLoS One. 2022; 17(7):e0270519.

PMID: 35802557 PMC: 9269451. DOI: 10.1371/journal.pone.0270519.


Comparison of ocular aberrations in three types of rigid gas permeable lenses in keratoconus patients.

Torkman S, Khabazkhoob M, Kangari H, Yekta A, Jafarzadehpur E Rom J Ophthalmol. 2020; 64(3):280-284.

PMID: 33367161 PMC: 7739550.


Short-term changes in topometric indices after discontinuation of rigid gas permeable lens wear in keratoconic eyes.

Kumar P, Ali M, Reddy J, Vaddavalli P Indian J Ophthalmol. 2020; 68(12):2911-2917.

PMID: 33229669 PMC: 7856990. DOI: 10.4103/ijo.IJO_1522_20.


References
1.
Wang X, McCulley J, Bowman R, Cavanagh H . Time to resolution of contact lens-induced corneal warpage prior to refractive surgery. CLAO J. 2002; 28(4):169-71. DOI: 10.1097/01.ICL.0000018042.02034.AB. View

2.
Romero-Jimenez M, Santodomingo-Rubido J, Flores-Rodriguez P, Gonzalez-Meijome J . Which soft contact lens power is better for piggyback fitting in keratoconus?. Cont Lens Anterior Eye. 2012; 36(1):45-8. DOI: 10.1016/j.clae.2012.10.070. View

3.
Jinabhai A, ODonnell C, Radhakrishnan H . Changes in refraction, ocular aberrations, and corneal structure after suspending rigid gas-permeable contact lens wear in keratoconus. Cornea. 2012; 31(5):500-8. DOI: 10.1097/ICO.0b013e31820f777b. View

4.
Hwang J, Lee J, Wee W, Kim M . Effects of multicurve RGP contact lens use on topographic changes in keratoconus. Korean J Ophthalmol. 2010; 24(4):201-6. PMC: 2916100. DOI: 10.3341/kjo.2010.24.4.201. View

5.
Lam A, Douthwaite W . Derivation of corneal flattening factor, p-value. Ophthalmic Physiol Opt. 1994; 14(4):423-7. View