Date 2014 Sep 7
PMID 25193884
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Passive-dynamic ankle-foot orthoses utilize stiffness to improve gait performance through elastic energy storage and return. However, the influence of ankle-foot orthosis stiffness on gait performance has not been systematically investigated, largely due to the difficulty of manufacturing devices with precisely controlled stiffness levels. Additive manufacturing techniques such as selective laser sintering have been used to successfully manufacture ankle-foot orthoses with controlled stiffness levels. The purpose of this study was to use passive-dynamic ankle-foot orthoses manufactured with selective laser sintering to identify the influence of orthosis stiffness on walking performance in patients with lower-limb neuromuscular and musculoskeletal impairments.

Methods: Thirteen subjects with unilateral impairments were enrolled in this study. For each subject, one passive-dynamic ankle-foot orthosis with stiffness equivalent to the subject's clinically prescribed carbon fiber orthosis, one 20% more compliant and one 20% more stiff, were manufactured using selective laser sintering. Three-dimensional kinematic and kinetic data and electromyographic data were collected from each subject while they walked overground with each orthosis at their self-selected velocity and a controlled velocity.

Findings: As the orthosis stiffness decreased, ankle range of motion and medial gastrocnemius activity increased while the knee became more extended throughout stance. Minimal changes in other kinematic, kinetic and electromyographic quantities were observed.

Interpretation: Subjects effectively compensated for changes in ankle-foot orthosis stiffness with altered gastrocnemius activity, and the stiffness levels analyzed in this study had a minimal effect on overall walking performance.

Citing Articles

Customized passive-dynamic ankle-foot orthoses can improve walking economy and speed for many individuals post-stroke.

Skigen J, Koller C, Nigro L, Reisman D, McKee Z, Pinhey S J Neuroeng Rehabil. 2024; 21(1):126.

PMID: 39069629 PMC: 11285468. DOI: 10.1186/s12984-024-01425-7.


Minimization of metabolic cost of transport predicts changes in gait mechanics over a range of ankle-foot orthosis stiffnesses in individuals with bilateral plantar flexor weakness.

Kiss B, Waterval N, van der Krogt M, Brehm M, Geijtenbeek T, Harlaar J Front Bioeng Biotechnol. 2024; 12:1369507.

PMID: 38846804 PMC: 11153850. DOI: 10.3389/fbioe.2024.1369507.


Advancing Exoskeleton Development: Validation of a Robotic Surrogate to Measure Tibial Strain.

McGrath R, Price C, Johnson W, Childers W Bioengineering (Basel). 2024; 11(5).

PMID: 38790357 PMC: 11118925. DOI: 10.3390/bioengineering11050490.


A Review of Additive Manufacturing Studies for Producing Customized Ankle-Foot Orthoses.

Silva R, Veloso A, Alves N, Fernandes C, Morouco P Bioengineering (Basel). 2022; 9(6).

PMID: 35735492 PMC: 9219792. DOI: 10.3390/bioengineering9060249.


Ankle-foot orthosis with an oil damper versus nonarticulated ankle-foot orthosis in the gait of patients with subacute stroke: a randomized controlled trial.

Yamamoto S, Motojima N, Kobayashi Y, Osada Y, Tanaka S, Daryabor A J Neuroeng Rehabil. 2022; 19(1):50.

PMID: 35619141 PMC: 9137172. DOI: 10.1186/s12984-022-01027-1.