» Articles » PMID: 25190922

A Novel Method for Blood Volume Estimation Using Trivalent Chromium in Rabbit Models

Overview
Publisher Thieme
Specialty General Surgery
Date 2014 Sep 6
PMID 25190922
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Blood volume measurement though important in management of critically ill-patients is not routinely estimated in clinical practice owing to labour intensive, intricate and time consuming nature of existing methods.

Aims: The aim was to compare blood volume estimations using trivalent chromium [(51)Cr(III)] and standard Evans blue dye (EBD) method in New Zealand white rabbit models and establish correction-factor (CF).

Materials And Methods: Blood volume estimation in 33 rabbits was carried out using EBD method and concentration determined using spectrophotometric assay followed by blood volume estimation using direct injection of (51)Cr(III). Twenty out of 33 rabbits were used to find CF by dividing blood volume estimation using EBD with blood volume estimation using (51)Cr(III). CF is validated in 13 rabbits by multiplying it with blood volume estimation values obtained using (51)Cr(III).

Results: The mean circulating blood volume of 33 rabbits using EBD was 142.02 ± 22.77 ml or 65.76 ± 9.31 ml/kg and using (51)Cr(III) was estimated to be 195.66 ± 47.30 ml or 89.81 ± 17.88 ml/kg. The CF was found to be 0.77. The mean blood volume of 13 rabbits measured using EBD was 139.54 ± 27.19 ml or 66.33 ± 8.26 ml/kg and using (51)Cr(III) with CF was 152.73 ± 46.25 ml or 71.87 ± 13.81 ml/kg (P = 0.11).

Conclusions: The estimation of blood volume using (51)Cr(III) was comparable to standard EBD method using CF. With further research in this direction, we envisage human blood volume estimation using (51)Cr(III) to find its application in acute clinical settings.

Citing Articles

Preclinical evaluation of efficacy and pharmacokinetics of gentamicin containing extracellular-matrix envelope.

Sohail M, Esquer Garrigos Z, Elayi C, Xiang K, Catanzaro J Pacing Clin Electrophysiol. 2020; 43(3):341-349.

PMID: 32067241 PMC: 7155100. DOI: 10.1111/pace.13888.


Serial blood volume estimation in rabbits using trivalent chromium - An exploratory study.

Baby P, Kumar P, Kumar R, Jacob S, Rawat D, Vs B MethodsX. 2019; 6:1068-1071.

PMID: 31193381 PMC: 6527811. DOI: 10.1016/j.mex.2019.05.009.


Evans Blue Dye: A Revisit of Its Applications in Biomedicine.

Yao L, Xue X, Yu P, Ni Y, Chen F Contrast Media Mol Imaging. 2018; 2018:7628037.

PMID: 29849513 PMC: 5937594. DOI: 10.1155/2018/7628037.


Loss of pleckstrin-2 reverts lethality and vascular occlusions in JAK2V617F-positive myeloproliferative neoplasms.

Zhao B, Mei Y, Cao L, Zhang J, Sumagin R, Yang J J Clin Invest. 2017; 128(1):125-140.

PMID: 29202466 PMC: 5749534. DOI: 10.1172/JCI94518.


An innovative approach for serial injection in marginal vein and blood collection from auricular artery in New Zealand white Rabbit.

Baby P, Jacob S, Kumar R, Kumar P MethodsX. 2017; 4:457-460.

PMID: 29167756 PMC: 5686422. DOI: 10.1016/j.mex.2017.11.001.


References
1.
Shippy C, Appel P, Shoemaker W . Reliability of clinical monitoring to assess blood volume in critically ill patients. Crit Care Med. 1984; 12(2):107-12. DOI: 10.1097/00003246-198402000-00005. View

2.
Cook D . Clinical assessment of central venous pressure in the critically ill. Am J Med Sci. 1990; 299(3):175-8. DOI: 10.1097/00000441-199003000-00006. View

3.
Jahr J, Lurie F, Xi S, Golkaryeh M, Kuznetsova O, Kullar R . A novel approach to measuring circulating blood volume: the use of a hemoglobin-based oxygen carrier in a rabbit model. Anesth Analg. 2001; 92(3):609-14. DOI: 10.1097/00000539-200103000-00010. View

4.
NOBLE R, GREGERSEN M, Porter P, Buckman A . BLOOD VOLUME IN CLINICAL SHOCK. I. MIXING TIME AND DISAPPEARANCE RATE OF T-1824 IN NORMAL SUBJECTS AND IN PATIENTS IN SHOCK; DETERMINATION OF PLASMA VOLUME IN MAN FROM 10-MINUTE SAMPLE. J Clin Invest. 1946; 25(2):158-71. PMC: 435551. DOI: 10.1172/JCI101695. View

5.
Jones J, Wardrop C . Measurement of blood volume in surgical and intensive care practice. Br J Anaesth. 2000; 84(2):226-35. DOI: 10.1093/oxfordjournals.bja.a013407. View