Estimating the Value of Surgical Clips for Target Volume Delineation in External Beam Partial Breast Radiotherapy

Overview
Specialty Oncology
Date 2014 Sep 2
PMID 25175041
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Aims: To investigate the role of surgical clips in defining the clinical target volume (CTV) for three-dimensional conformal external beam radiotherapy-partial breast irradiation (3D-CRT-PBI) using preoperative computed tomography scans.

Materials And Methods: A group of patients with early breast cancer underwent conservative surgery with placement of surgical titanium clips (at least three clips required). All patients had a treatment planning computed tomography simulation before (CT1) and after surgery (CT2). The two sets of images were co-registered with a match point registration. The relationship between the clips-based CTV for PBI delineated on CT2 and the initial tumour location on CT1 was studied, evaluating the percentage of intersection volume.

Results: Twenty-eight patients participated in this study. In total, 13 patients (46.4%) had an intersection volume ≥ 50% and 10 patients (35.7%) had complete intersection (intersection volume = 100%). An increased median intersection volume was observed in patients with more than six clips (P = 0.007) and in patients with a larger portion of breast volume covered by the PBI-CTV (CTV/BV; P = 0.010). Intersection volume increased with the number of clips, after adjustment for CTV/BV (linear coefficient = 5.1693; P = 0.043). Also, a maximum distance from the chest wall ≤0.7 cm and CTV/BV > 9.5% were found to be predictors of an intersection volume ≥50% (area under the curve 0.841; confidence interval 0.649-0.952; P < 0.0001; area under the curve 0.800; confidence interval 0.607-0.926; P = 0.0004) and of an intersection volume of 100% (area under the curve 0.776, confidence interval 0.573-0.916, P = 0.046; area under the curve 0.752, confidence interval 0.536-0.935; P = 0.032).

Conclusions: Titanium clips are essential and six or more increase the accuracy of tumour bed delineation for PBI; also the primary tumour location as well as the percentage of volume of breast covered by PBI-CTV may influence the correct delineation of PBI-CTV.

Citing Articles

Target volumes comparison between postoperative simulation magnetic resonance imaging and preoperative diagnostic magnetic resonance imaging for prone breast radiotherapy after breast-conserving surgery.

Jin Y, Zhao C, Wang L, Su Y, Shang D, Li F Cancer Med. 2024; 13(3):e6956.

PMID: 38247382 PMC: 10905334. DOI: 10.1002/cam4.6956.


Review of Current Accepted Practices in Identification of the Breast Lumpectomy Tumor Bed.

Acree P, Kapadia A, Mahatme R, Zhang L, Patel D, Almoney C Adv Radiat Oncol. 2022; 7(5):100848.

PMID: 36148372 PMC: 9486415. DOI: 10.1016/j.adro.2021.100848.


Partial Breast Irradiation and Surgical Clip Usage for Tumor Bed Delineation After Breast-Conserving Surgery in Canada: A Radiation Oncology Perspective.

Koch C, Corey G, Liu Z, Han K, Fyles A Adv Radiat Oncol. 2021; 6(4):100701.

PMID: 34409206 PMC: 8360935. DOI: 10.1016/j.adro.2021.100701.


A novel, adaptable, radiographically opaque, multi-plane continuous filament marker for optimizing tissue identification, radiation planning, and radiographic follow-up.

Mitchell S, Lee H, DuPree B, Beyer D, Ulissey M, Grobmyer S Gland Surg. 2020; 8(6):609-617.

PMID: 32042667 PMC: 6989892. DOI: 10.21037/gs.2019.10.03.


A topology-based method to mitigate the dosimetric uncertainty caused by the positional variation of the boost volume in breast conservative radiotherapy.

Lee P, Lin C, Chen S, Chien C, Chu C, Hsu H Radiat Oncol. 2017; 12(1):55.

PMID: 28320428 PMC: 5359879. DOI: 10.1186/s13014-017-0801-4.