High and Ultra-high B-value Diffusion-weighted Imaging in Prostate Cancer: a Quantitative Analysis
Overview
Authors
Affiliations
Background: Diffusion-weighted imaging (DWI) is routinely used in magnetic resonance imaging (MRI) of prostate cancer. However, the routine use of b values higher than 1000 s/mm(2) is not clear up to present. Moreover, the complex diffusion behavior of malignant and benign prostate tissues hampers precise predictions of contrast in DWI images and apparent diffusion coefficient (ADC) maps.
Purpose: To quantitatively analyze DWI with different b values in prostate cancer and to identify b values best suitable for cancer detection.
Material And Methods: Forty-one patients with histologically proven prostate cancer were examined with high resolution T2-weighted imaging and DWI at 3 Tesla. Five different b values (0, 800, 1000, 1500, 2000 s/mm(2)) were applied. ADC values of tumors and reference areas were measured on ADC maps derived from different pairs of b values. Furthermore, signal intensities of DW images of tumors and reference areas were measured. For analysis, contrast ratios of ADC values and signal intensities of DW images were calculated and compared.
Results: No significant differences were found between contrast ratios measured on ADC maps of all analyzed b value pairs (P = 0.43). Contrast ratios calculated from signal intensities of DW images were highest at b values of 1500 and 2000 s/mm(2) and differed significantly from contrast ratios at b values of 800 and 1000 s/mm(2) (P < 0.01).
Conclusion: Whereas contrast in ADC maps does not significantly change with different b values, contrast ratios of DW images are significantly higher at b-values of 1500 and 2000 s/mm(2) in comparison to b values of 800 and 1000 s/mm(2). Therefore, diagnostic performance of DWI in prostate cancer might be increased by application of b values higher than 1000 s/mm(2).
Quantitative magnetic resonance imaging in prostate cancer: A review of current technology.
Dhiman A, Kumar V, Das C World J Radiol. 2024; 16(10):497-511.
PMID: 39494137 PMC: 11525833. DOI: 10.4329/wjr.v16.i10.497.
Palumbo P, Martinese A, Antenucci M, Granata V, Fusco R, De Muzio F Gland Surg. 2024; 12(12):1806-1822.
PMID: 38229839 PMC: 10788566. DOI: 10.21037/gs-23-53.
Feasibility of diffusion weighting with a local inside-out nonlinear gradient coil for prostate MRI.
Hoque Bhuiyan E, Dewdney A, Weinreb J, Galiana G Med Phys. 2021; 48(10):5804-5818.
PMID: 34287937 PMC: 9152877. DOI: 10.1002/mp.15100.
Hu Y, Yan L, Han Y, Duan S, Sun Q, Li G BMC Med Imaging. 2020; 20(1):14.
PMID: 32041549 PMC: 7011602. DOI: 10.1186/s12880-020-0419-0.
Signal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer.
A R, M J T, N C, M S, M Gh H, Gh A J Biomed Phys Eng. 2019; 9(4):453-458.
PMID: 31531298 PMC: 6709361. DOI: 10.31661/jbpe.v0i0.811.