» Articles » PMID: 25078303

Inactivation of Natural Enteric Bacteria in Real Municipal Wastewater by Solar Photo-Fenton at Neutral PH

Overview
Journal Water Res
Date 2014 Aug 1
PMID 25078303
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

This study analyses the use of the solar photo-Fenton treatment in compound parabolic collector photo-reactors at neutral pH for the inactivation of wild enteric Escherichia coli and total coliform present in secondary effluents of a municipal wastewater treatment plant (SEWWTP). Control experiments were carried out to find out the individual effects of mechanical stress, pH, reactants concentration, and UVA radiation as well as the combined effects of UVA-Fe and UVA-H2O2. The synergistic germicidal effect of solar-UVA with 50 mg L(-1) of H2O2 led to complete disinfection (up to the detection limit) of total coliforms within 120 min. The disinfection process was accelerated by photo-Fenton, achieving total inactivation in 60 min reducing natural bicarbonate concentration found in the SEWWTP from 250 to 100 mg L(-1) did not give rise to a significant enhancement in bacterial inactivation. Additionally, the effect of hydrogen peroxide and iron dosage was evaluated. The best conditions were 50 mg L(-1) of H2O2 and 20 mg L(-1) of Fe(2+). Due to the variability of the SEWWTP during autumn and winter seasons, the inactivation kinetic constant varied between 0.07 ± 0.04 and 0.17 ± 0.04 min(-1). Moreover, the water treated by solar photo-Fenton fulfilled the microbiological quality requirement for wastewater reuse in irrigation as per the WHO guidelines and in particular for Spanish legislation.

Citing Articles

Application of Photo-Fenton-Membrane Technology in Wastewater Treatment: A Review.

Liang L, Ji L, Ma Z, Ren Y, Zhou S, Long X Membranes (Basel). 2023; 13(4).

PMID: 37103796 PMC: 10142173. DOI: 10.3390/membranes13040369.


Challenges on solar oxidation as post-treatment of municipal wastewater from UASB systems: Treatment efficiency, disinfection and toxicity.

Rodrigues-Silva F, V M Starling M, C Amorim C Sci Total Environ. 2022; 850:157940.

PMID: 35952890 PMC: 9554792. DOI: 10.1016/j.scitotenv.2022.157940.


Wastewater Treatment by Advanced Oxidation Process and Their Worldwide Research Trends.

Garrido-Cardenas J, Esteban-Garcia B, Aguera A, Sanchez-Perez J, Manzano-Agugliaro F Int J Environ Res Public Health. 2019; 17(1).

PMID: 31881722 PMC: 6981484. DOI: 10.3390/ijerph17010170.


Analogies and differences among bacterial and viral disinfection by the photo-Fenton process at neutral pH: a mini review.

Giannakis S Environ Sci Pollut Res Int. 2017; 25(28):27676-27692.

PMID: 29255985 DOI: 10.1007/s11356-017-0926-x.


Ecotoxicity evaluation of a WWTP effluent treated by solar photo-Fenton at neutral pH in a raceway pond reactor.

Freitas A, Rivas G, Campos-Manas M, Casas Lopez J, Aguera A, Sanchez Perez J Environ Sci Pollut Res Int. 2016; 24(2):1093-1104.

PMID: 27335017 DOI: 10.1007/s11356-016-7101-7.