» Articles » PMID: 24961918

Small Molecule Specific Run Acceptance, Specific Assay Operation, and Chromatographic Run Quality Assessment: Recommendation for Best Practices and Harmonization from the Global Bioanalysis Consortium Harmonization Teams

Abstract

Consensus practices and regulatory guidance for liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) assays of small molecules are more aligned globally than for any of the other bioanalytical techniques addressed by the Global Bioanalysis Consortium. The three Global Bioanalysis Consortium Harmonization Teams provide recommendations and best practices for areas not yet addressed fully by guidances and consensus for small molecule bioanalysis. Recommendations from all three teams are combined in this report for chromatographic run quality, validation, and sample analysis run acceptance.

Citing Articles

Inclusion of dilution quality control samples in quantitative LC-MS bioanalysis.

Li W, Fu Y, Picard F Bioanalysis. 2024; 16(17-18):923-925.

PMID: 39324496 PMC: 11486123. DOI: 10.1080/17576180.2024.2352253.


Optimization of double-vortex-assisted matrix solid-phase dispersion for the rapid determination of paraben preservative residues in leafy vegetables.

Yang C, Chung W, Ding W RSC Adv. 2022; 10(58):35557-35564.

PMID: 35515645 PMC: 9056883. DOI: 10.1039/d0ra05658h.


A suggested standard for validation of LC-MS/MS based analytical series in diagnostic laboratories.

Vogeser M, Stone J Clin Mass Spectrom. 2021; 16:25-32.

PMID: 34820517 PMC: 8600988. DOI: 10.1016/j.clinms.2020.02.002.


Determination of KD025 (SLx-2119), a Selective ROCK2 Inhibitor, in Rat Plasma by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and its Pharmacokinetic Application.

Yoon J, Nguyen T, Duong V, Chun K, Maeng H Molecules. 2020; 25(6).

PMID: 32192179 PMC: 7144358. DOI: 10.3390/molecules25061369.


AAPS Workshop Report on ICH M10.

Booth B, Vazvaei F, Fluhler E, Myler H, Woolf E AAPS J. 2019; 22(1):10.

PMID: 31823177 PMC: 6904406. DOI: 10.1208/s12248-019-0398-7.


References
1.
Bergeron M, Bergeron A, Furtado M, Garofolo F . Impact of plasma and whole-blood anticoagulant counter ion choice on drug stability and matrix effects during bioanalysis. Bioanalysis. 2010; 1(3):537-48. DOI: 10.4155/bio.09.74. View

2.
Garofolo F, Rocci Jr M, Dumont I, Martinez S, Lowes S, Woolf E . 2011 White paper on recent issues in bioanalysis and regulatory findings from audits and inspections. Bioanalysis. 2011; 3(18):2081-96. DOI: 10.4155/bio.11.192. View

3.
Sennbro C, Knutsson M, Timmerman P, van Amsterdam P . Anticoagulant counter ion impact on bioanalytical LC-MS/MS assay performance: additional validation required?. Bioanalysis. 2011; 3(21):2389-91. DOI: 10.4155/bio.11.240. View

4.
Sennbro C, Knutsson M, van Amsterdam P, Timmerman P . Anticoagulant counter ion impact on bioanalytical LC-MS/MS assays: results from discussions and experiments within the European Bioanalysis Forum. Bioanalysis. 2011; 3(21):2393-9. DOI: 10.4155/bio.11.239. View