Poor Intermediate-term Survival of the Uncemented Optan Anatomically Adapted Femoral Component

Overview
Journal Acta Orthop
Specialty Orthopedics
Date 2014 Jun 24
PMID 24954492
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: We evaluated the 5-year survival of the uncemented Optan anatomically adapted femoral stem, with revision for aseptic loosening as the endpoint.

Methods: Between January 2004 and March 2007, 432 total hip arthroplasties (THAs) were performed in 432 patients. After follow-up for a mean time of 5 years, the patients were evaluated using the WOMAC questionnaire and plain radiography. Patients who were unable to attend the follow-up visit were contacted by telephone to determine whether they had had any revision surgery of their THA.

Results: Within 5 years, 39 patients (9%) had died of unrelated causes and 63 patients (15%) had been lost to follow-up. Of the remaining cohort, 224 patients (68%) had full follow-up while 88 patients (27%) were evaluated with WOMAC only and 18 patients (5%) were evaluated with radiography only. The mean WOMAC score of all evaluated patients was 21 (10-100). At 5-year follow-up, there were 26 stem revisions reported (6%), 14 hips (3%) showed aseptic loosening, and 12 hips (3%) had had a periprosthetic femoral fracture. The 5-year survival to revision for any reason was 94%. Worst-case analysis yielded a 5-year survival of 79%.

Interpretation: The 5-year survival for aseptic loosening of the Optan anatomically adapted femoral component was disappointing. Radiographic evaluation showed evidence of proximal radiolucencies and distal cortical bone hypertrophy, which we attribute to insufficient proximal bone in-growth and increased load transfer at the tip of the stem. We do not recommend the use of the Optan femoral stem.

References
1.
Roorda L, Jones C, Waltz M, Lankhorst G, Bouter L, van der Eijken J . Satisfactory cross cultural equivalence of the Dutch WOMAC in patients with hip osteoarthritis waiting for arthroplasty. Ann Rheum Dis. 2003; 63(1):36-42. PMC: 1754708. DOI: 10.1136/ard.2002.001784. View

2.
Wu C, Au M, Wu S, Lin L . Risk factors for postoperative femoral fracture in cementless hip arthroplasty. J Formos Med Assoc. 1999; 98(3):190-4. View

3.
Gruen T, McNeice G, Amstutz H . "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979; (141):17-27. View

4.
Decking R, Puhl W, Simon U, Claes L . Changes in strain distribution of loaded proximal femora caused by different types of cementless femoral stems. Clin Biomech (Bristol). 2006; 21(5):495-501. DOI: 10.1016/j.clinbiomech.2005.12.011. View

5.
Wittenberg R, Steffen R, Windhagen H, Bucking P, Wilcke A . Five-year results of a cementless short-hip-stem prosthesis. Orthop Rev (Pavia). 2013; 5(1):e4. PMC: 3662260. DOI: 10.4081/or.2013.e4. View