» Articles » PMID: 24899989

Usefulness of F-18 FDG PET/CT in Assessment of Recurrence of Cervical Cancer After Treatment

Overview
Publisher Springer
Date 2014 Jun 6
PMID 24899989
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Until now, serum tumor markers, physical examination, and conventional imaging modalities, such as CT or MRI, have been used in assessment of recurrence of cervical cancer after treatment. However, CT and MRI provide only anatomical data, which makes analysis of post-treatment change difficult. This study aims to explore the effectiveness of PET/CT, a new scanning device that combines PET and CT, in evaluation of cervical cancer lesions in patients with suspected recurrence.

Methods: We studied 51 patients suspected of recurrence among those who underwent F-18 FDG PET/CT for cervical cancer follow-up at Gachon University Gil Hospital between June 2006 and August 2009. Patients were considered to be at risk for recurrence if they reported symptoms that were clinically suggestive of recurrence, or if physical examination showed abnormalities, serum tumor marker levels rose, or follow-up images revealed changes, such as new lesions or swelling of previous sites. Sensitivity, accuracy, specificity, and positive and negative predictive values of PET/CT were measured.

Results: A total of 37 patients were confirmed with recurrence or metastasis, 13 of whom were diagnosed histologically. Measured across all patients, PET/CT scored 97.3% on sensitivity, 71.4% on specificity, a positive predictive value of 90%, a negative predictive value of 90.9%, and an accuracy of 90.2%. PET/CT yielded only one false negative diagnosis and four false positives.

Conclusion: As F-18 FDG PET/CT has high sensitivity and negative predictive value in diagnosis of recurrent cervical cancers, it is expected that it will be useful for clinical determination of recurrence and prevention of unnecessary additional treatments. The hope is that a future study on a larger scale will contribute further to determination of the efficacy of PET/CT.

Citing Articles

Relapsed Carcinoma Cervix Presented with Multiple Rare Visceral Metastases: Role of 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography.

Saini V, Markam K, Nazar A, Ora M, Gambhir S Indian J Nucl Med. 2023; 37(4):373-375.

PMID: 36817192 PMC: 9930453. DOI: 10.4103/ijnm.ijnm_58_22.


18F-FDG PET/computed tomography scan in patients with suspicion of recurrent neuroendocrine carcinoma of the cervix.

Jiang Y, Hou G, Huo L, Li F, Zhu Z, Cheng W Nucl Med Commun. 2021; 42(10):1151-1156.

PMID: 33927154 PMC: 8445361. DOI: 10.1097/MNM.0000000000001432.


[18F]-2-Fluoro-2-Deoxy-D-glucose-PET Assessment of Cervical Cancer.

Viswanathan C, Faria S, Devine C, Patnana M, Sagebiel T, Iyer R PET Clin. 2018; 13(2):165-177.

PMID: 29482748 PMC: 5996999. DOI: 10.1016/j.cpet.2017.11.004.


Practice guidelines for management of cervical cancer in Korea: a Korean Society of Gynecologic Oncology Consensus Statement.

Lim M, Lee M, Shim S, Nam E, Lee J, Kim H J Gynecol Oncol. 2017; 28(3):e22.

PMID: 28382794 PMC: 5391389. DOI: 10.3802/jgo.2017.28.e22.


Positron emission tomography alone, positron emission tomography-computed tomography and computed tomography in diagnosing recurrent cervical carcinoma: a systematic review and meta-analysis.

Xiao Y, Wei J, Zhang Y, Xiong W Arch Med Sci. 2014; 10(2):222-31.

PMID: 24904653 PMC: 4042042. DOI: 10.5114/aoms.2014.42572.


References
1.
Waggoner S . Cervical cancer. Lancet. 2003; 361(9376):2217-25. DOI: 10.1016/S0140-6736(03)13778-6. View

2.
Connor J, Andrews J, Anderson B, Buller R . Computed tomography in endometrial carcinoma. Obstet Gynecol. 2000; 95(5):692-6. DOI: 10.1016/s0029-7844(99)00626-2. View

3.
Kitajima K, Murakami K, Yamasaki E, Domeki Y, Kaji Y, Sugimura K . Performance of FDG-PET/CT for diagnosis of recurrent uterine cervical cancer. Eur Radiol. 2008; 18(10):2040-7. DOI: 10.1007/s00330-008-0979-9. View

4.
Delbeke D . Oncological applications of FDG PET imaging. J Nucl Med. 1999; 40(10):1706-15. View

5.
Beyer T, Townsend D, Brun T, Kinahan P, Charron M, Roddy R . A combined PET/CT scanner for clinical oncology. J Nucl Med. 2000; 41(8):1369-79. View