» Articles » PMID: 24887300

Continuous Veno-venous Hemofiltration to Adjust Fluid Volume Excess in Septic Shock Patients Reduces Intra-abdominal Pressure

Overview
Journal Clin Nephrol
Specialty Nephrology
Date 2014 Jun 3
PMID 24887300
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To analyze the effect and the time course of continuous veno-venous hemofiltration (CVVH) with net ultrafiltration (UF) on intra-abdominal pressure (IAP) body fluid volumes in septic shock patients with acute kidney injury (AKI).

Methods: Patients were studied at baseline and after 6, 12, 24, 48, 72, and 96 hours of CVVH treatment. IAP was measured via the bladder, and abdominal perfusion pressure (APP) was calculated as mean arterial pressure minus IAP. Fluid volume excess (VE), total body water (TBW), extracellular body water (ECW), and intracellular body water (ICW) were derived from wholebody bioimpedance analysis (BIA).

Results: 30 patients entered final analysis, of which 6 died during CVVH (non-survivors). Fluid VE, TBW, ECW, ICW, and IAP significantly decreased in 24 survivors, whereas these variables remained essentially unchangedin non-survivors. APP slowly increased in survivors, while it did not change in nonsurvivors. IAP strongly correlated with VEin survivors: The lower the IAP, the lower the fluid volume excess.

Conclusion: CVVH with net UF successfully reduced IAP, TBW, ECW, and ICW in critically ill patients who survived 96 h of CVVH. Failure to increase APP was associated with fatal outcome, and, finally, IAP correlated with fluid volume excess. BIA could be helpful to monitor fluid status in patients with AKI.

Citing Articles

Bioimpedance-Guided Fluid Removal in Continuous KRT: The VENUS Randomized Clinical Trial.

An J, Oh H, Oh S, Rhee H, Seong E, Baek S Clin J Am Soc Nephrol. 2024; 19(12):1527-1536.

PMID: 39264719 PMC: 11637699. DOI: 10.2215/CJN.0000000000000557.


Fluid accumulation syndrome in sepsis and septic shock: pathophysiology, relevance and treatment-a comprehensive review.

Pfortmueller C, Dabrowski W, Wise R, van Regenmortel N, Malbrain M Ann Intensive Care. 2024; 14(1):115.

PMID: 39033219 PMC: 11264678. DOI: 10.1186/s13613-024-01336-9.


Comparison of Bioelectrical Impedance Analysis (BIA)-Derived Parameters in Healthy Volunteers and Critically Ill Patients.

Cleymaet R, DHondt M, Scheinok T, Malbrain L, De Laet I, Schoonheydt K Life (Basel). 2024; 14(1).

PMID: 38255643 PMC: 10821189. DOI: 10.3390/life14010027.


Bioelectrical impedance analysis during deresuscitation: correlation and agreement with cumulative fluid balance in ICU patients.

Ruste M, Chabanol C, Fellahi J, Jacquet-Lagreze M J Clin Monit Comput. 2022; 37(2):679-687.

PMID: 36197549 DOI: 10.1007/s10877-022-00923-0.


Comparison of body water status and its distribution in patients with non-septic infection, patients with sepsis, and healthy controls.

Shin J, Park I, Lee J, Han J, Kim B, Jang D Clin Exp Emerg Med. 2021; 8(3):173-181.

PMID: 34649405 PMC: 8517463. DOI: 10.15441/ceem.20.094.