» Articles » PMID: 24877024

Intravital Imaging of Mouse Colonic Adenoma Using MMP-based Molecular Probes with Multi-channel Fluorescence Endoscopy

Overview
Specialty Radiology
Date 2014 May 31
PMID 24877024
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Intravital imaging has provided molecular, cellular and anatomical insight into the study of tumor. Early detection and treatment of gastrointestinal (GI) diseases can be enhanced with specific molecular markers and endoscopic imaging modalities. We present a wide-field multi-channel fluorescence endoscope to screen GI tract for colon cancer using multiple molecular probes targeting matrix metalloproteinases (MMP) conjugated with quantum dots (QD) in AOM/DSS mouse model. MMP9 and MMP14 antibody (Ab)-QD conjugates demonstrate specific binding to colonic adenoma. The average target-to-background (T/B) ratios are 2.10 ± 0.28 and 1.78 ± 0.18 for MMP14 Ab-QD and MMP9 Ab-QD, respectively. The overlap between the two molecular probes is 67.7 ± 8.4%. The presence of false negative indicates that even more number of targeting could increase the sensitivity of overall detection given heterogeneous molecular expression in tumors. Our approach indicates potential for the screening of small or flat lesions that are precancerous.

Citing Articles

Infrared thermal modulation endoscopy for label-free tumor detection.

Kim S, Oh G, Ro Kim Y, Chung E, Kwon H Sci Rep. 2024; 14(1):31575.

PMID: 39738048 PMC: 11685564. DOI: 10.1038/s41598-024-76173-8.


Confocal Endomicroscopy Monitoring of Tumor Formation.

Preaudet A, Fung K, Putoczki T Methods Mol Biol. 2023; 2691:257-262.

PMID: 37355552 DOI: 10.1007/978-1-0716-3331-1_20.


Intravital longitudinal cellular visualization of oral mucosa in a murine model based on rotatory side-view confocal endomicroscopy.

Hong S, Lee J, Moon J, Kong E, Jeon J, Kim Y Biomed Opt Express. 2022; 13(8):4160-4174.

PMID: 36032579 PMC: 9408257. DOI: 10.1364/BOE.462269.


Method for Acute Intravital Imaging of the Large Intestine in Live Mice.

Erreni M, Doni A, Weigert R Methods Mol Biol. 2021; 2304:285-299.

PMID: 34028723 DOI: 10.1007/978-1-0716-1402-0_15.


Enhancement of signal-to-noise ratio for fluorescence endoscope image based on fast digital lock-in algorithm.

Wang H, Hu M, Xia F, Guo M, Zhang S, Zhao Z R Soc Open Sci. 2021; 8(3):200779.

PMID: 33959306 PMC: 8074948. DOI: 10.1098/rsos.200779.


References
1.
Koblinski J, Ahram M, Sloane B . Unraveling the role of proteases in cancer. Clin Chim Acta. 2000; 291(2):113-35. DOI: 10.1016/s0009-8981(99)00224-7. View

2.
Lanza G, Messerini L, Gafa R, Risio M . Colorectal tumors: the histology report. Dig Liver Dis. 2011; 43 Suppl 4:S344-55. DOI: 10.1016/S1590-8658(11)60590-2. View

3.
Urano Y, Sakabe M, Kosaka N, Ogawa M, Mitsunaga M, Asanuma D . Rapid cancer detection by topically spraying a γ-glutamyltranspeptidase-activated fluorescent probe. Sci Transl Med. 2011; 3(110):110ra119. PMC: 7451965. DOI: 10.1126/scitranslmed.3002823. View

4.
Mitsunaga M, Kosaka N, Choyke P, Young M, Dextras C, Saud S . Fluorescence endoscopic detection of murine colitis-associated colon cancer by topically applied enzymatically rapid-activatable probe. Gut. 2012; 62(8):1179-86. PMC: 6309695. DOI: 10.1136/gutjnl-2011-301795. View

5.
Oshima M, Dinchuk J, Kargman S, Oshima H, Hancock B, Kwong E . Suppression of intestinal polyposis in Apc delta716 knockout mice by inhibition of cyclooxygenase 2 (COX-2). Cell. 1996; 87(5):803-9. DOI: 10.1016/s0092-8674(00)81988-1. View