The Impact of Continuous Glucose Monitoring on Low Interstitial Glucose Values and Low Blood Glucose Values Assessed by Point-of-care Blood Glucose Meters: Results of a Crossover Trial

Overview
Specialty Endocrinology
Date 2014 May 31
PMID 24876615
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

In a randomized crossover trial the impact of continuous glucose monitoring (CGM) was tested on the occurrence of low blood glucose values measured by point of care (POC) measurement and on low glucose values measured by CGM in the interstitial fluid. A total of 41 type 1 diabetic patients (age 42.0 ± 11.4 years, diabetes duration 15.3 ± 10.1 years, A1c 8.2 ± 1.4%) used a CGM system (Dexcom SEVEN PLUS system) twice. In first study phase (CGM blind), patients were blind regarding the CGM current glucose levels and were not alerted when critical glucose values were reached. In the second phase (CGM real time), patients had access to current glucose levels and were alerted if critical glucose values were reached. During CGM real time the proportion of hypoglycemic POC blood glucose values were significantly reduced (7.5 ± 5.6% vs 10.1 ± 7.5%; P = .04), whereas the proportion of euglycemic blood glucose values were significantly enhanced (73.7 ± 18.3% vs 68.3 ± 12.1%; P = .01). The duration of low glucose periods in the interstitial fluid was significantly lower in the CGM real time phase (125 ± 89 vs 181 ± 125 minutes per day; P = .005). The time until a low blood glucose was detected by POC measurement was shortened by 33.2 ± 76.1 minutes (P = .03). The study demonstrated that CGM is able to not only reduce duration of hypoglycemia measured by CGM in interstitial fluid, but also reduce the proportion of low POC blood glucose measurements. In addition, hypoglycemia can be detected earlier.

Citing Articles

Glycemia Risk Index is Associated With Risk of Albuminuria Among Individuals With Type 1 Diabetes.

Kim J, Yoo J, Kim N, Kim J J Diabetes Sci Technol. 2025; 19322968241310850.

PMID: 39773006 PMC: 11707761. DOI: 10.1177/19322968241310850.


2023 Clinical Practice Guidelines for Diabetes Management in Korea: Full Version Recommendation of the Korean Diabetes Association.

Moon J, Kang S, Choi J, Lee K, Moon J, Chon S Diabetes Metab J. 2024; 48(4):546-708.

PMID: 39091005 PMC: 11307112. DOI: 10.4093/dmj.2024.0249.


Continuous glucose monitoring with structured education in adults with type 2 diabetes managed by multiple daily insulin injections: a multicentre randomised controlled trial.

Kim J, Jin S, Sim K, Kim B, Cho J, Moon J Diabetologia. 2024; 67(7):1223-1234.

PMID: 38639876 DOI: 10.1007/s00125-024-06152-1.


7. Diabetes Technology: Standards of Care in Diabetes-2024.

Diabetes Care. 2023; 47(Suppl 1):S126-S144.

PMID: 38078575 PMC: 10725813. DOI: 10.2337/dc24-S007.


Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus.

Sacks D, Arnold M, Bakris G, Bruns D, Horvath A, Lernmark A Diabetes Care. 2023; 46(10):e151-e199.

PMID: 37471273 PMC: 10516260. DOI: 10.2337/dci23-0036.


References
1.
Mauras N, Fox L, Englert K, Beck R . Continuous glucose monitoring in type 1 diabetes. Endocrine. 2012; 43(1):41-50. DOI: 10.1007/s12020-012-9765-1. View

2.
Bergenstal R, Klonoff D, Garg S, Bode B, Meredith M, Slover R . Threshold-based insulin-pump interruption for reduction of hypoglycemia. N Engl J Med. 2013; 369(3):224-32. DOI: 10.1056/NEJMoa1303576. View

3.
Garg S, Kelly W, Voelmle M, Ritchie P, Gottlieb P, McFann K . Continuous home monitoring of glucose: improved glycemic control with real-life use of continuous glucose sensors in adult subjects with type 1 diabetes. Diabetes Care. 2007; 30(12):3023-5. DOI: 10.2337/dc07-1436. View

4.
Garg S, Smith J, Beatson C, Lopez-Baca B, Voelmle M, Gottlieb P . Comparison of accuracy and safety of the SEVEN and the Navigator continuous glucose monitoring systems. Diabetes Technol Ther. 2009; 11(2):65-72. DOI: 10.1089/dia.2008.0109. View

5.
Langendam M, Luijf Y, Hooft L, DeVries J, Mudde A, Scholten R . Continuous glucose monitoring systems for type 1 diabetes mellitus. Cochrane Database Syst Rev. 2012; 1:CD008101. PMC: 6486112. DOI: 10.1002/14651858.CD008101.pub2. View