Comparison of Baseline Tremor Under Various Microsurgical Conditions

Overview
Date 2014 Apr 23
PMID 24752457
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

This paper presents the characterization and comparison of physiological tremor for pointing tasks in multiple environments, as a baseline for performance evaluation of microsurgical robotics. Previous studies have examined the characteristics of physiological tremor under laboratory settings as well as different operating conditions. However, different test methods make the comparison of results across trials and conditions difficult. Two vitroretinal microsurgeons were evaluated while performing a pointing task with no entry-point constraint, constrained by an artificial eye model, and constrained by a rabbit eye in vivo. For the three respective conditions the 3D RMS positioning error was 144 μm, 258 μm, and 285 μm, and maximum 3D error was 349 μm, 647 μm, and 696 μm. A spectral analysis was also performed, confirming a distinct peak near in the 6-12 Hz frequency range, characteristic of hand tremor during tasks in all three environments.

Citing Articles

A Data-Driven Model with Hysteresis Compensation for IRIS Robot.

Esfandiari M, Zhou Y, Dehghani S, Hadi M, Munawar A, Phalen H Int Symp Med Robot. 2024; 2024.

PMID: 39421850 PMC: 11486515. DOI: 10.1109/ismr63436.2024.10585958.


A novel low-cost device for tool targeting training and microsurgical hand tremor assessment.

Bykanov A, Kiryushin M, Trube M, Rastvorova O, Ilia C, Pitskhelauri D Surg Neurol Int. 2024; 15:227.

PMID: 39108394 PMC: 11302592. DOI: 10.25259/SNI_271_2024.


Using a Microsurgical Robotic Platform for In-flap Anastomosis in Autologous Bipedicular Breast Reconstruction.

Vollbach F, Bigdeli A, Struebing F, Weigel J, Gazyakan E, Kneser U Plast Reconstr Surg Glob Open. 2024; 12(1):e5511.

PMID: 38204872 PMC: 10781112. DOI: 10.1097/GOX.0000000000005511.


Can Liquid Lenses Increase Depth of Field in Head Mounted Video See-Through Devices?.

Carbone M, Domeneghetti D, Cutolo F, DAmato R, Cigna E, Parchi P J Imaging. 2021; 7(8).

PMID: 34460773 PMC: 8404927. DOI: 10.3390/jimaging7080138.


Artificial intelligence and ophthalmic surgery.

Mishra K, Leng T Curr Opin Ophthalmol. 2021; 32(5):425-430.

PMID: 34397576 PMC: 10655904. DOI: 10.1097/ICU.0000000000000788.


References
1.
Halliday D, Conway B, Farmer S, Rosenberg J . Load-independent contributions from motor-unit synchronization to human physiological tremor. J Neurophysiol. 1999; 82(2):664-75. DOI: 10.1152/jn.1999.82.2.664. View

2.
Caligiuri M, Tripp R . A portable hand-held device for quantifying and standardizing tremor assessment. J Med Eng Technol. 2004; 28(6):254-62. DOI: 10.1080/03091900410001658111. View

3.
MacLachlan R, Becker B, Tabares J, Podnar G, Lobes Jr L, Riviere C . Micron: an Actively Stabilized Handheld Tool for Microsurgery. IEEE Trans Robot. 2012; 28(1):195-212. PMC: 3459596. DOI: 10.1109/TRO.2011.2169634. View

4.
Elble R, Randall J . Motor-unit activity responsible for 8- to 12-Hz component of human physiological finger tremor. J Neurophysiol. 1976; 39(2):370-83. DOI: 10.1152/jn.1976.39.2.370. View

5.
Latt W, Tan U, Veluvolu K, Lin J, Shee C, Ang W . System to assess accuracy of micromanipulation. Annu Int Conf IEEE Eng Med Biol Soc. 2007; 2007:5744-7. DOI: 10.1109/IEMBS.2007.4353651. View