Purpose: The aim of the study was to assess the influence of interimplant divergence on retention of two Locator attachments before and after in vitro simulation of 3 to 5 years of use.

Materials And Methods: A hydraulic universal testing machine was used to measure the retention of two blue Locator attachments during 5500 seating and unseating cycles. Ten pairs of Locators were tested with interimplant divergences of 0°, 10°, and 20°. Scanning electron microscopy (SEM) was used to examine surface changes of the components. The results were tested with ANOVA and Bonferroni post hoc correction when normally distributed. Results that were not normally distributed were tested with Kruskal-Wallis one-way ANOVA by ranks.

Results: At the start of the experiment the 10° group showed significantly more retention than the 0° group, but no significant difference was found between the 0° and 20° groups or the 10° and 20° groups. After 5500 cycles, there was no significant difference in retention between any of the groups. The SEM images showed an approximately equal amount of wear in the nylon patrix inserts from all the groups.

Conclusions: The retention of Locator pairs was not impaired by interimplant divergence of up to 20°. Retention after 5500 removal cycles was less than the initial retention in all groups. The nylon Locator patrices showed wear defects of similar location, type, and magnitude in the SEM images, regardless of interimplant angulation.

Citing Articles

Influence of Denture Cleansers on the Retention Loss of Attachment Systems Retained Implant Overdenture.

AlRumaih H, Albarrak A, AlMedaires M, Alsulaiman A, Baba N, Alshahrani F Int J Biomater. 2023; 2023:5077785.

PMID: 37159616 PMC: 10163970. DOI: 10.1155/2023/5077785.


Factors influencing retention and durability of attachments for overdentures - adverse effects of cleansings, pH, and temperature: A systematic review.

de Campos M, Marcondes Agnelli J, Dos Reis A Heliyon. 2022; 8(12):e12411.

PMID: 36582682 PMC: 9793270. DOI: 10.1016/j.heliyon.2022.e12411.


Effect of Implant Positions and Angulations on Retentive Strength of 2-Implant Mandibular Overdentures: An In Vitro Study with the New 3D-Printed Simulation Method.

Patil P, Seow L, Uddanwadikar R, Pau A, Ukey P Int J Dent. 2022; 2022:7052955.

PMID: 36160113 PMC: 9492357. DOI: 10.1155/2022/7052955.


Evaluation of Retention, Wear, and Maintenance of Attachment Systems for Single- or Two-Implant-Retained Mandibular Overdentures: A Systematic Review.

Wakam R, Benoit A, Mawussi K, Gorin C Materials (Basel). 2022; 15(5).

PMID: 35269164 PMC: 8911844. DOI: 10.3390/ma15051933.


Retentive Characteristics of a New Attachment System for Hybrid Dentures.

Arnold C, Stampa C, Schweyen R, Hey J, Boeckler A Materials (Basel). 2020; 13(15).

PMID: 32759744 PMC: 7436147. DOI: 10.3390/ma13153434.