» Articles » PMID: 24737254

Considerations on the Practical Application of the Size-specific Dose Estimation (SSDE) Method of AAPM Report 204

Overview
Date 2014 Apr 17
PMID 24737254
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Computed tomography (CT) is responsible for much of the radiation exposure to the population for medical purposes. The technique requires high doses that vary widely from center to center, and for different scanners and radiologists as well. In order to monitor doses to patients, the American Association of Physicists in Medicine has developed the size-specific dose estimate (SSDE), which consists of the determination of patient size dependent coefficients for converting the standard dosimetric index, CTDIvol, into an estimate of the dose actually absorbed by the patient. The present work deals with issues concerning the use of SSDE in the clinical practice. First the issue regarding how much SSDE varies when, for a given CT protocol, the scan covers slightly different volumes is addressed. Then, the differences among SSDE values derived from different patient size descriptors are investigated. For these purposes, data from a clinical archive are analyzed by an automatic procedure specifically developed for SSDE.

Citing Articles

A Study to Determine Whether the Volume-Weighted Computed Tomography Dose Index Gives Reasonable Estimates of Organ Doses for Thai Patients Undergoing Abdomen and Pelvis Computed Tomography Examinations.

Sookpeng S, Martin C, Butdee C J Med Phys. 2018; 42(4):266-272.

PMID: 29296042 PMC: 5744456. DOI: 10.4103/jmp.JMP_91_17.


Evaluation of AAPM Reports 204 and 220: Estimation of effective diameter, water-equivalent diameter, and ellipticity ratios for chest, abdomen, pelvis, and head CT scans.

Burton C, Szczykutowicz T J Appl Clin Med Phys. 2017; 19(1):228-238.

PMID: 29178549 PMC: 5768014. DOI: 10.1002/acm2.12223.


Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD).

Hui P, Goo H, Du J, Ip J, Kanzaki S, Kim Y Pediatr Radiol. 2017; 47(8):899-910.

PMID: 28435986 DOI: 10.1007/s00247-017-3847-4.

References
1.
Huda W, Sterzik A, Tipnis S, Schoepf U . Organ doses to adult patients for chest CT. Med Phys. 2010; 37(2):842-7. PMC: 2826387. DOI: 10.1118/1.3298015. View

2.
Li B, Behrman R . Comment on the "report of AAPM TG 204: size-specific dose estimates (SSDE) in pediatric and adult body CT examinations" [report of AAPM TG 204, 2011]. Med Phys. 2012; 39(7):4613-4. DOI: 10.1118/1.4725756. View

3.
McCollough C, Leng S, Yu L, Cody D, Boone J, McNitt-Gray M . CT dose index and patient dose: they are not the same thing. Radiology. 2011; 259(2):311-6. PMC: 3079120. DOI: 10.1148/radiol.11101800. View

4.
Boone J . Reply to "Comment on the 'Report of AAPM TG 204: Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations'" [AAPM Report 204, 2011]. Med Phys. 2017; 39(7Part2):4615-4616. PMC: 3412437. DOI: 10.1118/1.4725757. View

5.
Turner A, Zhang D, Khatonabadi M, Zankl M, DeMarco J, Cagnon C . The feasibility of patient size-corrected, scanner-independent organ dose estimates for abdominal CT exams. Med Phys. 2011; 38(2):820-9. PMC: 3037972. DOI: 10.1118/1.3533897. View