Surface Modification of Polydimethylsiloxane with a Covalent Antithrombin-heparin Complex to Prevent Thrombosis

Overview
Date 2014 Apr 17
PMID 24735089
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

To prevent coagulation in contact with blood, polydimethylsiloxane (PDMS) was modified with an antithrombin-heparin (ATH) covalent complex using polyethylene glycol (PEG) as a linker/spacer. Using NHS chemistry, ATH was attached covalently to the distal chain end of the immobilized PEG linker. Surfaces were characterized by contact angle and X-ray photoelectron spectroscopy; attachment was confirmed by decrease in contact angles and an increase in nitrogen content as determined by X-ray photoelectron spectroscopy. Protein interactions in plasma were investigated using radiolabeled proteins added to plasma as tracers, and by immunoblotting of eluted proteins. Modification of PDMS with PEG alone was effective in reducing non-specific protein adsorption; attachment of ATH at the distal end of the PEG chains did not significantly affect protein resistance. It was shown that surfaces modified with ATH bound antithrombin selectively from plasma through the pentasaccharide sequence on the heparin moiety of ATH, indicating the ability of the ATH-modified surfaces to inhibit coagulation. Using thromboelastography, the effect of ATH modification on plasma coagulation was evaluated directly. It was found that initiation of coagulation was delayed and the time to clot was prolonged on PDMS modified with ATH/PEG compared to controls. For comparison, surfaces modified in a similar way with heparin were prepared and investigated using the same methods. The data suggest that the ATH-modified surfaces have superior anticoagulant properties compared to those modified with heparin.

Citing Articles

Surface Coating with Hyaluronic Acid-Gelatin-Crosslinked Hydrogel on Gelatin-Conjugated Poly(dimethylsiloxane) for Implantable Medical Device-Induced Fibrosis.

Joo H, Park J, Sutthiwanjampa C, Kim H, Bae T, Kim W Pharmaceutics. 2021; 13(2).

PMID: 33671146 PMC: 7922955. DOI: 10.3390/pharmaceutics13020269.


A Pumpless Microfluidic Neonatal Lung Assist Device for Support of Preterm Neonates in Respiratory Distress.

Dabaghi M, Rochow N, Saraei N, Fusch G, Monkman S, Da K Adv Sci (Weinh). 2020; 7(21):2001860.

PMID: 33173732 PMC: 7610273. DOI: 10.1002/advs.202001860.


An artificial placenta type microfluidic blood oxygenator with double-sided gas transfer microchannels and its integration as a neonatal lung assist device.

Dabaghi M, Fusch G, Saraei N, Rochow N, Brash J, Fusch C Biomicrofluidics. 2019; 12(4):044101.

PMID: 30867861 PMC: 6404930. DOI: 10.1063/1.5034791.


Development and characterization of a stable adhesive bond between a poly(dimethylsiloxane) catheter material and a bacterial biofilm resistant acrylate polymer coating.

Tyler B, Hook A, Pelster A, Williams P, Alexander M, Arlinghaus H Biointerphases. 2017; 12(2):02C412.

PMID: 28535686 PMC: 5441992. DOI: 10.1116/1.4984011.