In-vivo 6 Degrees-of-freedom Kinematics of Metal-on-polyethylene Total Hip Arthroplasty During Gait

Overview
Journal J Biomech
Specialty Physiology
Date 2014 Apr 8
PMID 24704170
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Knowledge of accurate in-vivo 6 degree-of-freedom (6-DOF) kinematics of total hip arthroplasty (THA) during daily activities is critical for improvement of longevity of the components. Previous studies assessed in-vivo THA kinematics using skin marker-based motion analysis. However, skin markers are prone to move with respect to the underlying bones. A non-invasive dual fluoroscopic imaging system (DFIS) based tracking technique has been used to avoid skin artifacts and provide accurate 6-DOF kinematic measurement. This study aimed to quantify in-vivo 6-DOF THA kinematics during gait using DFIS. Twenty eight well-functioning THAs were evaluated during treadmill gait under DFIS surveillance. The maximum translations of the femoral head were 0.46±0.10mm and 0.45±0.10mm during the stance and swing phases (p=0.57), respectively. The range of hip flexion was from 8.7° to 47.6°, adduction from 3.0° to 12.5° and external rotation from 19.2° to 29.7°. The THA was flexed, externally rotated and adducted throughout the gait. The magnitudes of the femoral head translations were found to be within the manufacture tolerance of the components, suggesting that in-vivo hip "pistoning" during gait cycle may be minimal in well-functioning THAs. The 6-DOF kinematics could be used as the baseline knowledge for further improvement of wear-testing of hip implant, implants manufacturing and implant positioning during surgery.

Citing Articles

Moving fluoroscopy-based analysis of THA kinematics during unrestricted activities of daily living.

DIsidoro F, Brockmann C, Friesenbichler B, Zumbrunn T, Leunig M, Ferguson S Front Bioeng Biotechnol. 2023; 11:1095845.

PMID: 37168610 PMC: 10164959. DOI: 10.3389/fbioe.2023.1095845.


Postoperative Hip Center Position Associated With the Range of Internal Rotation and Extension During Gait in Hip Dysplasia Patients After Total Hip Arthroplasty.

Hu Y, Zou D, Sun Q, Jiang M, Li H, Tsai T Front Bioeng Biotechnol. 2022; 10:831647.

PMID: 35295644 PMC: 8918532. DOI: 10.3389/fbioe.2022.831647.


Does treadmill workstation use affect user's kinematic gait symmetry?.

Arauz P, Garcia M, Velez M, Leon C, Velez F, Martin B PLoS One. 2021; 16(12):e0261140.

PMID: 34905578 PMC: 8670710. DOI: 10.1371/journal.pone.0261140.


A new 2D-3D registration gold-standard dataset for the hip joint based on uncertainty modeling.

DIsidoro F, Chenes C, Ferguson S, Schmid J Med Phys. 2021; 48(10):5991-6006.

PMID: 34287934 PMC: 9290855. DOI: 10.1002/mp.15124.


Optimizing the Femoral Offset for Restoring Physiological Hip Muscle Function in Patients With Total Hip Arthroplasty.

Hu X, Zheng N, Chen Y, Dai K, Dimitriou D, Li H Front Bioeng Biotechnol. 2021; 9:645019.

PMID: 33869155 PMC: 8045972. DOI: 10.3389/fbioe.2021.645019.