» Articles » PMID: 24688346

Urgent Cesarean Section in a Patient with a Spinal Cord Stimulator: Implications for Surgery and Anesthesia

Overview
Journal Ochsner J
Specialty General Medicine
Date 2014 Apr 2
PMID 24688346
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Spinal cord stimulation used in the treatment of chronic pain is offered to women of child-bearing age. This practice warrants special consideration on the part of the obstetricians and anesthesiologists charged with their care.

Case Report: We report the instance of a parturient with a spinal cord stimulator who presented for urgent cesarean section. In spite of the patient's daunting back examination, the suitability of neuraxial anesthesia for cesarean delivery was rapidly determined by accessing images in our centerwide electronic medical record system.

Conclusion: Accepted approaches to managing labor and delivery-such as neuraxial anesthesia and analgesia-need not be denied patients with spinal cord stimulators. Whenever possible, however, the pain specialist should communicate the specific characteristics of the implanted device to the team who will manage the patient in the peripartal period.

Citing Articles

[Spinal anesthesia for patients harboring a neurostimulator].

Reining M, Voigt K, Gonnert F, Stolarczyk Y, Kretzschmar M Anaesthesiologie. 2022; 71(10):789-792.

PMID: 35925155 DOI: 10.1007/s00101-022-01128-5.


Recent publications by ochsner authors: october 2013 - march 2014.

Ochsner J. 2014; 14(2):301-6.

PMID: 24940149 PMC: 4052558.

References
1.
Bernardini D, Pratt S, Takoudes T, Simopoulos T . Spinal cord stimulation and the pregnant patient-specific considerations for management: A case series and review of the literature. Neuromodulation. 2011; 13(4):270-4. DOI: 10.1111/j.1525-1403.2010.00288.x. View

2.
Jacobs M, Jorning P, Joshi S, Kitslaar P, Slaaf D, Reneman R . Epidural spinal cord electrical stimulation improves microvascular blood flow in severe limb ischemia. Ann Surg. 1988; 207(2):179-83. PMC: 1493372. DOI: 10.1097/00000658-198802000-00011. View

3.
Ito S, Sugiura T, Azami T, Sasano H, Sobue K . Spinal cord stimulation for a woman with complex regional pain syndrome who wished to get pregnant. J Anesth. 2012; 27(1):124-7. DOI: 10.1007/s00540-012-1462-y. View

4.
Loge D, Devulder J, De Coster O, De Colvenaer L, Mortier E . The epidural fibrous sheath: a guide for the replacement of a spinal cord stimulation electrode. Reg Anesth Pain Med. 2002; 27(4):353-6. DOI: 10.1053/rapm.2002.33314. View

5.
Sommerfield D, Hu P, OKeeffe D, McKeating A K . Caesarean section in a parturient with a spinal cord stimulator. Int J Obstet Anesth. 2009; 19(1):114-7. DOI: 10.1016/j.ijoa.2009.08.006. View