Manual Aspiration Technique to Retrieve a Prematurely Detached Coil During Cerebral Aneurysm Embolization

Overview
Date 2014 Mar 20
PMID 24642890
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Coil herniation, premature deployment, and fracture are procedure associated complications of endovascular aneurysm embolization that optimally necessitate coil retrieval when feasible. Several published techniques describe different strategies for managing coil complications including various snare retrieval devices, alligator retrieval devices, stent fixation, and open surgical resection of coils when distal blood flow is compromised. We report a novel technique employed to retrieve a prematurely detached coil during an aneurysm embolization using a syringe fixed to the microcatheter to carefully aspirate a loose coil with direct fluoroscopic visualization. This technique can only be utilized in the circumstance where the proximal end of the coil remains in the microcatheter. Conventional techniques of coil retrieval and stenting are discussed and compared to the rational for using the manual aspiration technique.

Citing Articles

Parent artery stenting as a rescue management for stretched coils during cerebral aneurysms embolization: Report of three cases and review of literature.

Abdelrady M, Ognard J, Abdelsamad A, Mahmoud M Interv Neuroradiol. 2021; 28(5):613-622.

PMID: 34713746 PMC: 9511625. DOI: 10.1177/15910199211051556.


Retrieval of migrated coils with stent retrievers: an animal study.

Nikoubashman O, Pjontek R, Brockmann M, Tolba R, Wiesmann M AJNR Am J Neuroradiol. 2015; 36(6):1162-6.

PMID: 25678479 PMC: 8013012. DOI: 10.3174/ajnr.A4240.

References
1.
Thornton J, Dovey Z, Alazzaz A, Misra M, Aletich V, Debrun G . Surgery following endovascular coiling of intracranial aneurysms. Surg Neurol. 2001; 54(5):352-60. DOI: 10.1016/s0090-3019(00)00337-2. View

2.
Ng P, Halbach V, Caragine L, Dowd C, Higashida R . Guglielmi detachable coil extraction: suction generated by pusher-wire withdrawal after coil detachment within an intracranial aneurysm. AJNR Am J Neuroradiol. 2003; 24(5):982-4. PMC: 7975790. View

3.
Heuer G, Zaghloul K, Roberts R, Stiefel M, Storm P . Successful microsurgical extraction of a migrated coil in a pediatric patient after failed endovascular closure of a Blalock-Taussig shunt. Case report. J Neurosurg. 2007; 106(2 Suppl):136-8. DOI: 10.3171/ped.2007.106.2.136. View

4.
Koseoglu K, Parildar M, Oran I, Memis A . Retrieval of intravascular foreign bodies with goose neck snare. Eur J Radiol. 2004; 49(3):281-5. DOI: 10.1016/S0720-048X(03)00078-0. View

5.
Shin Y, Lee K, Kim D, Lee K, Huh S . Emergency surgical recanalisation of A1 segment occluded by a Guglielmi detachable coil. J Clin Neurosci. 2000; 7(3):259-62. DOI: 10.1054/jocn.1999.0207. View