» Articles » PMID: 24638258

One-step Antibody Immobilization-based Rapid and Highly-sensitive Sandwich ELISA Procedure for Potential in Vitro Diagnostics

Overview
Journal Sci Rep
Specialty Science
Date 2014 Mar 19
PMID 24638258
Citations 26
Authors
Affiliations
Soon will be listed here.
Abstract

An improved enzyme-linked immunosorbent (ELISA) assay using one-step antibody immobilization has been developed for the detection of human fetuin A (HFA), a specific biomarker for atherosclerosis and hepatocellular carcinoma. The anti-HFA formed a stable complex with 3-aminopropyltriethoxysilane (APTES) by ionic and hydrophobic interactions. The complex adsorbed on microtiter plates exhibited a detection range of 4.9 pg mL(-1) to 20 ng mL(-1) HFA, with a limit of detection of 7 pg mL(-1). Furthermore, an analytical sensitivity of 10 pg mL(-1) was achieved, representing a 51-fold increase in sensitivity over the commercial sandwich ELISA kit. The results obtained for HFA spiked in diluted human whole blood and plasma showed the same precision as the commercial kit. When stored at 4°C in 0.1 M phosphate-buffered saline (PBS, pH 7.4), the anti-HFA bound microtiter plates displayed no significant decrease in their functional activity after two months. The new ELISA procedure was extended for the detection of C-reactive protein, human albumin and human lipocalin-2 with excellent analytical performance.

Citing Articles

Development and Characterization of a Polyvalent Polyclonal Antibody as a Common Capture Antibody for the Detection of Enterotoxigenic Escherichia coli in a Sandwich ELISA.

Saldana-Ahuactzi Z, Gutierrez-Flores J, Luna-Pineda V, Cortes-Sarabia K, Avelino-Flores F, Orduna-Diaz A Curr Microbiol. 2025; 82(4):177.

PMID: 40053185 DOI: 10.1007/s00284-025-04154-9.


Tau biosensor on aptamer-modified interdigitated electrode for monitoring neurological effect caused by anesthesia.

Gao H, Qin H, Fu H, Feng J, Chen M Heliyon. 2024; 10(18):e37449.

PMID: 39309811 PMC: 11415702. DOI: 10.1016/j.heliyon.2024.e37449.


Genetic Functionalization of Protein-Based Biomaterials via Protein Fusions.

Mendes G, Faulk B, Kaparthi B, Irion A, Fong B, Bayless K Biomacromolecules. 2024; 25(8):4639-4662.

PMID: 39074364 PMC: 11323028. DOI: 10.1021/acs.biomac.4c00188.


Rapid, Direct, Noninvasive Method to Determine the Amount of Immobilized Protein.

Ambrozic R, Mravljak R, Podgornik A Anal Chem. 2023; 95(13):5643-5651.

PMID: 36939216 PMC: 10077329. DOI: 10.1021/acs.analchem.2c05402.


Antibody Immobilization.

Matson R Methods Mol Biol. 2023; 2612:33-44.

PMID: 36795357 DOI: 10.1007/978-1-0716-2903-1_3.


References
1.
Dixit C, Vashist S, Maccraith B, OKennedy R . Multisubstrate-compatible ELISA procedures for rapid and high-sensitivity immunoassays. Nat Protoc. 2011; 6(4):439-45. DOI: 10.1038/nprot.2011.304. View

2.
Drake R, Schwegler E, Malik G, Diaz J, Block T, Mehta A . Lectin capture strategies combined with mass spectrometry for the discovery of serum glycoprotein biomarkers. Mol Cell Proteomics. 2006; 5(10):1957-67. DOI: 10.1074/mcp.M600176-MCP200. View

3.
Jethwaney D, Lepore T, Hassan S, Mello K, Rangarajan R, Jahnen-Dechent W . Fetuin-A, a hepatocyte-specific protein that binds Plasmodium berghei thrombospondin-related adhesive protein: a potential role in infectivity. Infect Immun. 2005; 73(9):5883-91. PMC: 1231124. DOI: 10.1128/IAI.73.9.5883-5891.2005. View

4.
Zheng D, Vashist S, Dykas M, Saha S, Al-Rubeaan K, Lam E . Graphene Multi-Walled Carbon Nanotubes for Electrochemical Glucose Biosensing. Materials (Basel). 2017; 6(3):1011-1027. PMC: 5512961. DOI: 10.3390/ma6031011. View

5.
Wang Z, Jin G . Silicon surface modification with a mixed silanes layer to immobilize proteins for biosensor with imaging ellipsometry. Colloids Surf B Biointerfaces. 2004; 34(3):173-7. DOI: 10.1016/j.colsurfb.2003.12.012. View