» Articles » PMID: 24591222

Design and Validation of a Thermoreversible Material for Percutaneous Tissue Hydrodissection

Overview
Date 2014 Mar 5
PMID 24591222
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Interventional oncology procedures such as thermal ablation are becoming routine for many cancers. Hydrodissection-separating tissues with fluids-protects tissues near the treatment zone to improve ablation's safety and facilitate more aggressive treatments. However, currently used fluids such as normal saline and 5% dextrose in water (D5W) migrate in the peritoneum, reducing their protective efficacy. As a hydrodissection alternative, we investigated a thermoreversible poloxamer 407 (P407) solution. Such a material can be injected as a liquid which then forms a semi-solid gel at body temperature without syneresis. The desired gelation temperature of 32°C was achieved with 15.4 wt/wt % P407. Viscosity analysis revealed the lowest viscosity and ideal injection point was at 14°C. Solution viscosity increased during gelation, to a peak of 65 kPa*s at 40°C. The electrical impedance of P407 was significantly greater than isotonic saline, but lower than D5W, indicating its potential for electrical protection. The P407 gel was similar to other hydrodissection fluids at ultrasound and CT imaging. Ex vivo liver ablations showed that P407 protects neighboring tissues, but may require a thicker barrier for comparable protection to D5W. Overall, we found that the P407 solution is a feasible alternative to traditional hydrodissection fluids and warrants additional study.

Citing Articles

Development and preclinical evaluation of multifunctional hydrogel for precise thermal protection during thermal ablation.

Zheng B, Zhang P, Lv Q, Wu T, Liu Y, Tang J Bioact Mater. 2023; 31:119-135.

PMID: 37637083 PMC: 10448243. DOI: 10.1016/j.bioactmat.2023.08.010.


Healing Enhancement Assessment of Thermosensitive in Situ Gelling Formulation Containing Metronidazole and Diclofenac Potassium for Ligature-induced Periodontitis 
in Rats.

Wadi N, Ahuja A, Peh K Oman Med J. 2022; 37(3):e381.

PMID: 35722242 PMC: 9194917. DOI: 10.5001/omj.2022.66.


Sustained volume decreases in simple renal cysts after sclerotherapy using NBCA with or without hydrodissection.

Cardenas-Vargas M, Ortiz M, Izquierdo-Vega J, Diaz-Zamudio M J Interv Med. 2021; 4(1):15-20.

PMID: 34805942 PMC: 8562247. DOI: 10.1016/j.jimed.2020.10.002.


Effect of a poloxamer 407-based thermosensitive gel on minimization of thermal injury to diaphragm during microwave ablation of the liver.

Zhang L, Xia G, Liu Y, Dou R, Eisenbrey J, Liu J World J Gastroenterol. 2017; 23(12):2141-2148.

PMID: 28405141 PMC: 5374125. DOI: 10.3748/wjg.v23.i12.2141.


Microwave ablation in primary and secondary liver tumours: technical and clinical approaches.

Meloni M, Chiang J, Laeseke P, Dietrich C, Sannino A, Solbiati M Int J Hyperthermia. 2016; 33(1):15-24.

PMID: 27416729 PMC: 5235993. DOI: 10.1080/02656736.2016.1209694.


References
1.
Gervais D, McGovern F, Arellano R, McDougal W, Mueller P . Renal cell carcinoma: clinical experience and technical success with radio-frequency ablation of 42 tumors. Radiology. 2003; 226(2):417-24. DOI: 10.1148/radiol.2262012062. View

2.
Singh-Joy S, McLain V . Safety assessment of poloxamers 101, 105, 108, 122, 123, 124, 181, 182, 183, 184, 185, 188, 212, 215, 217, 231, 234, 235, 237, 238, 282, 284, 288, 331, 333, 334, 335, 338, 401, 402, 403, and 407, poloxamer 105 benzoate, and poloxamer 182 dibenzoate.... Int J Toxicol. 2008; 27 Suppl 2:93-128. DOI: 10.1080/10915810802244595. View

3.
Yu L, Ding J . Injectable hydrogels as unique biomedical materials. Chem Soc Rev. 2008; 37(8):1473-81. DOI: 10.1039/b713009k. View

4.
Rhim H, Lim H, Kim Y, Choi D . Percutaneous radiofrequency ablation with artificial ascites for hepatocellular carcinoma in the hepatic dome: initial experience. AJR Am J Roentgenol. 2007; 190(1):91-8. DOI: 10.2214/AJR.07.2384. View

5.
Webb H, Lubner M, Hinshaw J . Thermal ablation. Semin Roentgenol. 2011; 46(2):133-41. DOI: 10.1053/j.ro.2010.08.002. View