Acquisition techniques related to 4-dimensional (4D) flow magnetic resonance imaging (MRI) improved rapidly over the last 3 decades. Most importantly, a major improvement was the acceleration of the acquisition, which resulted in a clinically feasible scan duration and led to more comprehensive use of 4D flow MRI in clinical research. This resulted in several new applications of 4D flow MRI for the evaluation of various physiological and pathologic cardiovascular flow patterns. Visualization tools aim at displaying the direction and magnitude of blood flow velocity from 4D flow data, by using for instance a vector glyph or streamline representation or by constructing pathlines from particle tracing. Such tools are applied to provide insight in the temporal distribution of the 3D flow velocity and enable the quantification of hemodynamic markers. These hemodynamic markers play an important role in the quantitation of abnormalities in cardiovascular blood flow patterns and the characterization of vascular and myocardial remodelling, which can possibly be used to predict pathology such as heart failure, aortic dissection, or aneurysm or thrombus formation. This review focuses on the clinical use of 4D flow MRI and presents an overview of new applications of visualization and quantification tools to describe physiological and pathologic cardiovascular blood flow.

Citing Articles

Biomechanics in the tumor microenvironment: from biological functions to potential clinical applications.

Peng H, Chao Z, Wang Z, Hao X, Xi Z, Ma S Exp Hematol Oncol. 2025; 14(1):4.

PMID: 39799341 PMC: 11724500. DOI: 10.1186/s40164-024-00591-7.


Combined free-running four-dimensional anatomical and flow magnetic resonance imaging with native contrast using Synchronization of Neighboring Acquisitions by Physiological Signals.

Falcao M, Mackowiak A, Rossi G, Prsa M, Tenisch E, Rumac S J Cardiovasc Magn Reson. 2024; 26(1):101006.

PMID: 38309581 PMC: 11211232. DOI: 10.1016/j.jocmr.2024.101006.


4D Flow cardiovascular magnetic resonance consensus statement: 2023 update.

Bissell M, Raimondi F, Ait Ali L, Allen B, Barker A, Bolger A J Cardiovasc Magn Reson. 2023; 25(1):40.

PMID: 37474977 PMC: 10357639. DOI: 10.1186/s12968-023-00942-z.


Pilot tone navigation for respiratory and cardiac motion-resolved free-running 5D flow MRI.

Falcao M, Di Sopra L, Ma L, Bacher M, Yerly J, Speier P Magn Reson Med. 2021; 87(2):718-732.

PMID: 34611923 PMC: 8627452. DOI: 10.1002/mrm.29023.


Validation of aortic valve 4D flow analysis and myocardial deformation by cardiovascular magnetic resonance in patients after the arterial switch operation.

van Wijk W, Breur J, Westenberg J, Driessen M, Meijboom F, Driesen B J Cardiovasc Magn Reson. 2019; 21(1):20.

PMID: 30879465 PMC: 6421716. DOI: 10.1186/s12968-019-0527-6.