» Articles » PMID: 24562029

Comparative Analysis of Discrete and Continuous Absorption Weighting Estimators Used in Monte Carlo Simulations of Radiative Transport in Turbid Media

Overview
Specialty Ophthalmology
Date 2014 Feb 25
PMID 24562029
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

We examine the relative error of Monte Carlo simulations of radiative transport that employ two commonly used estimators that account for absorption differently, either discretely, at interaction points, or continuously, between interaction points. We provide a rigorous derivation of these discrete and continuous absorption weighting estimators within a stochastic model that we show to be equivalent to an analytic model, based on the radiative transport equation (RTE). We establish that both absorption weighting estimators are unbiased and, therefore, converge to the solution of the RTE. An analysis of spatially resolved reflectance predictions provided by these two estimators reveals no advantage to either in cases of highly scattering and highly anisotropic media. However, for moderate to highly absorbing media or isotropically scattering media, the discrete estimator provides smaller errors at proximal source locations while the continuous estimator provides smaller errors at distal locations. The origin of these differing variance characteristics can be understood through examination of the distribution of exiting photon weights.

Citing Articles

Monte Carlo simulation of spatial frequency domain imaging for breast tumors during compression.

Robbins C, Qian K, Zhang Y, Kainerstorfer J J Biomed Opt. 2024; 29(9):096001.

PMID: 39282216 PMC: 11399730. DOI: 10.1117/1.JBO.29.9.096001.


Analysis of relative error in perturbation Monte Carlo simulations of radiative transport.

Parsanasab M, Hayakawa C, Spanier J, Shen Y, Venugopalan V J Biomed Opt. 2023; 28(6):065001.

PMID: 37293394 PMC: 10245552. DOI: 10.1117/1.JBO.28.6.065001.


Hybrid Monte Carlo estimators for multilayer transport problems.

Zhao S, Spanier J J Comput Phys. 2022; 431.

PMID: 36338317 PMC: 9632332. DOI: 10.1016/j.jcp.2021.110117.


MCCL: an open-source software application for Monte Carlo simulations of radiative transport.

Hayakawa C, Malenfant L, Ranasinghesagara J, Cuccia D, Spanier J, Venugopalan V J Biomed Opt. 2022; 27(8).

PMID: 35415991 PMC: 9005200. DOI: 10.1117/1.JBO.27.8.083005.


Predictive model for the quantitative analysis of human skin using photothermal radiometry and diffuse reflectance spectroscopy.

Verdel N, Tanevski J, Dzeroski S, Majaron B Biomed Opt Express. 2020; 11(3):1679-1696.

PMID: 32206435 PMC: 7075612. DOI: 10.1364/BOE.384982.


References
1.
Alerstam E, Svensson T, Andersson-Engels S . Parallel computing with graphics processing units for high-speed Monte Carlo simulation of photon migration. J Biomed Opt. 2009; 13(6):060504. DOI: 10.1117/1.3041496. View

2.
Hiraoka M, Firbank M, Essenpreis M, Cope M, Arridge S, van der Zee P . A Monte Carlo investigation of optical pathlength in inhomogeneous tissue and its application to near-infrared spectroscopy. Phys Med Biol. 1993; 38(12):1859-76. DOI: 10.1088/0031-9155/38/12/011. View

3.
Doronin A, Meglinski I . Online object oriented Monte Carlo computational tool for the needs of biomedical optics. Biomed Opt Express. 2011; 2(9):2461-9. PMC: 3184856. DOI: 10.1364/BOE.2.002461. View

4.
Wang L, Jacques S, Zheng L . MCML--Monte Carlo modeling of light transport in multi-layered tissues. Comput Methods Programs Biomed. 1995; 47(2):131-46. DOI: 10.1016/0169-2607(95)01640-f. View

5.
Sassaroli A, Martelli F . Equivalence of four Monte Carlo methods for photon migration in turbid media. J Opt Soc Am A Opt Image Sci Vis. 2012; 29(10):2110-7. DOI: 10.1364/JOSAA.29.002110. View