» Articles » PMID: 24554291

Acoustic Radiation Force Impulse Imaging (ARFI) on an IVUS Circular Array

Overview
Date 2014 Feb 21
PMID 24554291
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Our long-term goal is the detection and characterization of vulnerable plaque in the coronary arteries of the heart using intravascular ultrasound (IVUS) catheters. Vulnerable plaque, characterized by a thin fibrous cap and a soft, lipid-rich necrotic core is a precursor to heart attack and stroke. Early detection of such plaques may potentially alter the course of treatment of the patient to prevent ischemic events. We have previously described the characterization of carotid plaques using external linear arrays operating at 9 MHz. In addition, we previously modified circular array IVUS catheters by short-circuiting several neighboring elements to produce fixed beamwidths for intravascular hyperthermia applications. In this paper, we modified Volcano Visions 8.2 French, 9 MHz catheters and Volcano Platinum 3.5 French, 20 MHz catheters by short-circuiting portions of the array for acoustic radiation force impulse imaging (ARFI) applications. The catheters had an effective transmit aperture size of 2 mm and 1.5 mm, respectively. The catheters were connected to a Verasonics scanner and driven with pushing pulses of 180 V p-p to acquire ARFI data from a soft gel phantom with a Young's modulus of 2.9 kPa. The dynamic response of the tissue-mimicking material demonstrates a typical ARFI motion of 1 to 2 microns as the gel phantom displaces away and recovers back to its normal position. The hardware modifications applied to our IVUS catheters mimic potential beamforming modifications that could be implemented on IVUS scanners. Our results demonstrate that the generation of radiation force from IVUS catheters and the development of intravascular ARFI may be feasible.

Citing Articles

Development of an intravascular ultrasound elastography based on a dual-element transducer.

Shih C, Chen P, Ma T, Zhou Q, Shung K, Huang C R Soc Open Sci. 2018; 5(4):180138.

PMID: 29765694 PMC: 5936959. DOI: 10.1098/rsos.180138.


Ultrasonic Shear Wave Elasticity Imaging Sequencing and Data Processing Using a Verasonics Research Scanner.

Deng Y, Rouze N, Palmeri M, Nightingale K IEEE Trans Ultrason Ferroelectr Freq Control. 2017; 64(1):164-176.

PMID: 28092508 PMC: 5266610. DOI: 10.1109/TUFFC.2016.2614944.


Jitter reduction technique for acoustic radiation force impulse microscopy via photoacoustic detection.

Kang B, Yoon C, Park J, Hwang J, Shung K Opt Express. 2015; 23(15):19166-75.

PMID: 26367579 PMC: 4523556. DOI: 10.1364/OE.23.019166.


An adaptive displacement estimation algorithm for improved reconstruction of thermal strain.

Ding X, Dutta D, Mahmoud A, Tillman B, Leers S, Kim K IEEE Trans Ultrason Ferroelectr Freq Control. 2015; 62(1):138-51.

PMID: 25585398 PMC: 4295651. DOI: 10.1109/TUFFC.2014.006516.

References
1.
Back M, Bowser A, Johnson B, Schmacht D, Zwiebel B, Bandyk D . Patency of infrarenal aortic side branches determines early aneurysm sac behavior after endovascular repair. Ann Vasc Surg. 2003; 17(1):27-34. DOI: 10.1007/s10016-001-0327-x. View

2.
Le Floch S, Ohayon J, Tracqui P, Finet G, Gharib A, Maurice R . Vulnerable atherosclerotic plaque elasticity reconstruction based on a segmentation-driven optimization procedure using strain measurements: theoretical framework. IEEE Trans Med Imaging. 2009; 28(7):1126-37. PMC: 4764048. DOI: 10.1109/TMI.2009.2012852. View

3.
Lee W, Idriss S, Wolf P, Smith S . A miniaturized catheter 2-D array for real-time, 3-D intracardiac echocardiography. IEEE Trans Ultrason Ferroelectr Freq Control. 2004; 51(10):1334-46. DOI: 10.1109/tuffc.2004.1350962. View

4.
Palmeri M, Wang M, Dahl J, Frinkley K, Nightingale K . Quantifying hepatic shear modulus in vivo using acoustic radiation force. Ultrasound Med Biol. 2008; 34(4):546-58. PMC: 2362504. DOI: 10.1016/j.ultrasmedbio.2007.10.009. View

5.
Nightingale K, Palmeri M, Nightingale R, Trahey G . On the feasibility of remote palpation using acoustic radiation force. J Acoust Soc Am. 2001; 110(1):625-34. DOI: 10.1121/1.1378344. View