» Articles » PMID: 24523063

Sensitivity-enhanced Chemical Exchange Saturation Transfer (CEST) MRI with Least Squares Optimization of Carr Purcell Meiboom Gill Multi-echo Echo Planar Imaging

Overview
Specialty Radiology
Date 2014 Feb 14
PMID 24523063
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Chemical exchange saturation transfer (CEST) imaging is a novel MRI technique that is sensitive to biomolecules, local pH and temperature, and offers considerable advantages for in vivo applications. However, the magnitude of CEST effect for dilute CEST agents undergoing slow or intermediate chemical exchange is typically small, requiring the use of signal averaging to enhance its sensitivity. Given that T2 -induced signal loss can be normalized by asymmetry analysis, the magnitude of CEST effect is independent of echo time. Therefore, CEST MRI with multi-echo echo planar imaging (EPI) readout should yield the same CEST effect as conventional single echo acquisition. Importantly, CEST multi-echo (CESTme) EPI images can be averaged to enhance CEST MRI sensitivity. The goal of this study was to validate CESTme EPI using a creatine-agarose gel CEST phantom with similar T2 as biological tissue. Using least-squares optimization, we found that the sensitivity of CESTme sequence was significantly higher than that obtained by conventional single echo CEST-EPI acquisition. Specifically, signal-to-noise ratio and contrast-to-noise ratio from the proposed CESTme EPI were approximately equivalent to that obtained by doubling the number of signal averages of the standard single echo CEST MRI sequence. In summary, our results demonstrated CESTme EPI for sensitivity-enhanced CEST imaging.

Citing Articles

Proton Exchange Magnetic Resonance Imaging: Current and Future Applications in Psychiatric Research.

Shaffer Jr J, Mani M, Schmitz S, Xu J, Owusu N, Wu D Front Psychiatry. 2020; 11:532606.

PMID: 33192650 PMC: 7542226. DOI: 10.3389/fpsyt.2020.532606.


CEST MR-Fingerprinting: Practical considerations and insights for acquisition schedule design and improved reconstruction.

Perlman O, Herz K, Zaiss M, Cohen O, Rosen M, Farrar C Magn Reson Med. 2019; 83(2):462-478.

PMID: 31400034 PMC: 7190069. DOI: 10.1002/mrm.27937.


Simultaneous pH-sensitive and oxygen-sensitive MRI of human gliomas at 3 T using multi-echo amine proton chemical exchange saturation transfer spin-and-gradient echo echo-planar imaging (CEST-SAGE-EPI).

Harris R, Yao J, Chakhoyan A, Raymond C, Leu K, Liau L Magn Reson Med. 2018; 80(5):1962-1978.

PMID: 29626359 PMC: 6107417. DOI: 10.1002/mrm.27204.


A theoretical analysis of chemical exchange saturation transfer echo planar imaging (CEST-EPI) steady state solution and the CEST sensitivity efficiency-based optimization approach.

Jiang W, Zhou I, Wen L, Zhou X, Sun P Contrast Media Mol Imaging. 2016; 11(5):415-423.

PMID: 27312932 PMC: 5069132. DOI: 10.1002/cmmi.1699.


Fast simulation and optimization of pulse-train chemical exchange saturation transfer (CEST) imaging.

Xiao G, Sun P, Wu R Phys Med Biol. 2015; 60(12):4719-30.

PMID: 26020414 PMC: 4555213. DOI: 10.1088/0031-9155/60/12/4719.


References
1.
Sun P, Sorensen A . Imaging pH using the chemical exchange saturation transfer (CEST) MRI: Correction of concomitant RF irradiation effects to quantify CEST MRI for chemical exchange rate and pH. Magn Reson Med. 2008; 60(2):390-7. DOI: 10.1002/mrm.21653. View

2.
Ward K, Balaban R . Determination of pH using water protons and chemical exchange dependent saturation transfer (CEST). Magn Reson Med. 2000; 44(5):799-802. DOI: 10.1002/1522-2594(200011)44:5<799::aid-mrm18>3.0.co;2-s. View

3.
Cai K, Haris M, Singh A, Kogan F, Greenberg J, Hariharan H . Magnetic resonance imaging of glutamate. Nat Med. 2012; 18(2):302-6. PMC: 3274604. DOI: 10.1038/nm.2615. View

4.
Schmitt B, Zaiss M, Zhou J, Bachert P . Optimization of pulse train presaturation for CEST imaging in clinical scanners. Magn Reson Med. 2011; 65(6):1620-9. DOI: 10.1002/mrm.22750. View

5.
Zhu H, Jones C, van Zijl P, Barker P, Zhou J . Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brain. Magn Reson Med. 2010; 64(3):638-44. PMC: 2932772. DOI: 10.1002/mrm.22546. View