Abstract

Errors in kinematic data are referred to as noise and are an undesirable portion of any waveform. Noise is typically removed using a low-pass filter which removes the high frequency components of the signal. The selection of an optimal frequency cut-off is very important when processing kinematic information and a number of techniques exists for the determination of an optimal frequency cut-off. Despite the importance of cut-off frequency to the efficacy of kinematic analyses there is currently a paucity of research examining the influence of different cut-off frequencies on the resultant 3-D kinematic waveforms and discrete parameters. Twenty participants ran at 4.0 m•s-1 as lower extremity kinematics in the sagittal, coronal and transverse planes were measured using an eight camera motion analysis system. The data were filtered at a range of cut-off frequencies and the discrete kinematic parameters were examined using repeated measures ANOVA's. The similarity between the raw and filtered waveforms were examined using intra-class correlations. The results show that the cut-off frequency has a significant influence on the discrete kinematic measure across displacement and derivative information in all three planes of rotation. Furthermore, it was also revealed that as the cut-off frequency decreased the attenuation of the kinematic waveforms became more pronounced, particularly in the coronal and transverse planes at the second derivative. In conclusion, this investigation provides new information regarding the influence of digital filtering on lower extremity kinematics and re-emphasizes the importance of selecting the correct cut-off frequency.

Citing Articles

Knee joint mechanics during gait after anterior cruciate ligament reconstruction using a partial or full thickness quadriceps tendon autograft at 2 years after surgery.

Ripic Z, Letter M, Parrino R, Adams W, Kaplan L, Baraga M PM R. 2024; 17(3):310-318.

PMID: 39548878 PMC: 11889528. DOI: 10.1002/pmrj.13278.


Walking on different inclines affects gait symmetry differently in the anterior-posterior and vertical directions: implication for future sensorimotor training.

Xie H, Chien J PeerJ. 2024; 12:e18096.

PMID: 39301058 PMC: 11412221. DOI: 10.7717/peerj.18096.


Kinematic synergies show good consistency when extracted with a low-cost markerless device and a marker-based motion tracking system.

Brambilla C, Scano A Heliyon. 2024; 10(11):e32042.

PMID: 38882310 PMC: 11176860. DOI: 10.1016/j.heliyon.2024.e32042.


The effect of dopaminergic treatment on whole body kinematics explored through network theory.

Romano A, Liparoti M, Minino R, Polverino A, Cipriano L, Carotenuto A Sci Rep. 2024; 14(1):1913.

PMID: 38253728 PMC: 10803322. DOI: 10.1038/s41598-023-50546-x.


Females with hip-related pain demonstrate reduced kinetics at the hip and ankle during terminal stance of gait.

Grosklos M, Lewis C, Ceballos E, Perry J, Di Stasi S Gait Posture. 2023; 105:99-103.

PMID: 37515892 PMC: 10527984. DOI: 10.1016/j.gaitpost.2023.07.284.


References
1.
Winter D, Sidwall H, Hobson D . Measurement and reduction of noise in kinematics of locomotion. J Biomech. 1974; 7(2):157-9. DOI: 10.1016/0021-9290(74)90056-6. View

2.
Sinclair J, Richards J, Taylor P, Edmundson C, Brooks D, Hobbs S . Three-dimensional kinematic comparison of treadmill and overground running. Sports Biomech. 2013; 12(3):272-82. DOI: 10.1080/14763141.2012.759614. View

3.
Robertson D, Dowling J . Design and responses of Butterworth and critically damped digital filters. J Electromyogr Kinesiol. 2003; 13(6):569-73. DOI: 10.1016/s1050-6411(03)00080-4. View

4.
Soudan K, Dierckx P . Calculation of derivatives and Fouriercoefficients of human motion data, while using spline functions. J Biomech. 1979; 12(1):21-6. DOI: 10.1016/0021-9290(79)90005-8. View

5.
Zernicke R, Caldwell G, Roberts E . Fitting biomechanical data with cubic spline functions. Res Q. 1976; 47(1):9-19. View