» Articles » PMID: 24511213

A Capacitive MEMS Viscometric Sensor for Affinity Detection of Glucose

Overview
Date 2014 Feb 11
PMID 24511213
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

This paper presents a capacitively based microelectromechanical systems affinity sensor for continuous glucose monitoring (CGM) applications. This sensor consists of a vibrating Parylene diaphragm, which is remotely driven by a magnetic field and situated inside a microchamber. A solution of poly(acrylamide-ran-3-acrylamidophenylboronic acid) (PAA--PAAPBA), a biocompatible glucose-sensitive polymer, fills the microchamber, which is separated from its surroundings by a semipermeable membrane. Glucose permeates through the membrane and binds reversibly to the phenylboronic acid moiety of the polymer. This results in a viscosity change of the sensing solution, causing a detectable change in the Parylene diaphragm vibration which can be measured capacitively. Experimental results demonstrate that the device is capable of detecting glucose at physiologically relevant concentrations ranging from 30 to 360 mg/dL. The response time of the sensor to glucose concentration changes is approximately 1.5 min, which can be further improved with optimized device designs. Excellent reversibility and stability are observed in sensor responses, as highly desired for long-term CGM.

Citing Articles

Biomimetic pulsatile flows through flexible microfluidic conduits.

Raj M K, DasGupta S, Chakraborty S Biomicrofluidics. 2019; 13(1):014103.

PMID: 30867874 PMC: 6404934. DOI: 10.1063/1.5065901.


Flow-induced deformation in a microchannel with a non-Newtonian fluid.

Raj M K, Chakraborty J, DasGupta S, Chakraborty S Biomicrofluidics. 2018; 12(3):034116.

PMID: 30018695 PMC: 6019333. DOI: 10.1063/1.5036632.


Glucose Sensing Using Capacitive Biosensor Based on Polyvinylidene Fluoride Thin Film.

Hartono A, Sanjaya E, Ramli R Biosensors (Basel). 2018; 8(1).

PMID: 29385694 PMC: 5872060. DOI: 10.3390/bios8010012.


A hydrogel-based glucose affinity microsensor.

Shang J, Yan J, Zhang Z, Huang X, Maturavongsadit P, Song B Sens Actuators B Chem. 2016; 237:992-998.

PMID: 27721570 PMC: 5050552. DOI: 10.1016/j.snb.2016.03.146.


A continuous glucose monitoring device by graphene modified electrochemical sensor in microfluidic system.

Pu Z, Zou C, Wang R, Lai X, Yu H, Xu K Biomicrofluidics. 2016; 10(1):011910.

PMID: 26958097 PMC: 4769273. DOI: 10.1063/1.4942437.


References
1.
Wang J, Chatrathi M, Tian B, Polsky R . Microfabricated electrophoresis chips for simultaneous bioassays of glucose, uric acid, ascorbic acid, and acetaminophen. Anal Chem. 2000; 72(11):2514-8. DOI: 10.1021/ac991489l. View

2.
Heller A . Implanted electrochemical glucose sensors for the management of diabetes. Annu Rev Biomed Eng. 2001; 1:153-75. DOI: 10.1146/annurev.bioeng.1.1.153. View

3.
Kataoka T, Sakurai Y . Immunogenicity and amplifier cell production by tumor vaccines enhanced by concanavalin A. Gan. 1982; 73(2):193-205. View

4.
Matsuura H, Ranganathan S, Yamamoto M, Kattke B . Studies on the effect of concanavalin A on the metabolism of low density lipoproteins in skin fibroblasts. Jpn J Med. 1987; 26(3):323-5. DOI: 10.2169/internalmedicine1962.26.323. View

5.
Li S, Huang X, Davis E, Lin Q, Wang Q . Development of novel glucose sensing fluids with potential application to microelectromechanical systems-based continuous glucose monitoring. J Diabetes Sci Technol. 2009; 2(6):1066-74. PMC: 2769820. DOI: 10.1177/193229680800200615. View