Abstract

Easy and innovative non-dispersive ionic liquid based microextraction (NDILME) has been developed for preconcentration of trace level of cadmium (Cd) in aqueous real surface water samples prior to couple with graphite furnace atomic absorption spectrometry (GFAAS). A 200 cm long narrow glass column containing aqueous solution of standard/sample was used to increase phase transfer ratio by providing more contact area between two medium (aqueous and extractive), which drastically improve the recoveries of labile hydrophobic chelate of Cd ammonium pyrrolidinedithiocarbamate (APDC), into ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate [C4mim][PF6]. Different aspect of the desire method have been investigated and optimized. Under the optimized key experimental variables, limit of detection (LOD) and enhancement factor (EF) were achieved to be 0.5 ng L(-1) and 150, respectively. Reliability of the model method was checked by relative standard deviation (%RSD), which was found to be <5%. Validity and accuracy of the developed method was checked by analysis of certified reference water samples (SLRS-4 Riverine water) using standard addition method. Application of the model method was productively performed by analysis of Cd in real surface water samples (tap and sea).

Citing Articles

Development of a Sensitive Method for Cadmium Determination in Fish Tissue and Drinking Water Samples by FAAS Using SQT In Situ Atom Trapping.

Karababa H, Atasoy M, Yildiz D, Kula I, Tuzen M ACS Omega. 2023; 8(7):7063-7069.

PMID: 36844526 PMC: 9947951. DOI: 10.1021/acsomega.2c07926.


Vortex-assisted switchable liquid-liquid microextraction for the preconcentration of cadmium in environmental samples prior to its determination with flame atomic absorption spectrometry.

Firat M, Bodur S, Tisli B, Ozlu C, Chormey D, Turak F Environ Monit Assess. 2018; 190(7):393.

PMID: 29892908 DOI: 10.1007/s10661-018-6786-0.


Trace monitoring of silver ions in food and water samples by flame atomic absorption spectrophotometry after preconcentration with solvent-assisted dispersive solid phase extraction.

Omidi F, Behbahani M, Shahtaheri S, Salimi S Environ Monit Assess. 2015; 187(6):361.

PMID: 25980728 DOI: 10.1007/s10661-015-4568-5.


Preconcentration and determination of lead and cadmium levels in blood samples of adolescent workers consuming smokeless tobacco products in Pakistan.

Arain S, Kazi T, Afridi H, Brahman K, Naeemullah , Khan S Environ Monit Assess. 2015; 187(5):309.

PMID: 25930204 DOI: 10.1007/s10661-015-4543-1.


Determination of nickel in blood and serum samples of oropharyngeal cancer patients consumed smokeless tobacco products by cloud point extraction coupled with flame atomic absorption spectrometry.

Arain S, Kazi T, Arain J, Afridi H, Kazi A, Nasreen S Environ Sci Pollut Res Int. 2014; 21(20):12017-27.

PMID: 24920259 DOI: 10.1007/s11356-014-3091-5.