» Articles » PMID: 24460486

More Accurate Neuronavigation Data Provided by Biomechanical Modeling Instead of Rigid Registration

Overview
Journal J Neurosurg
Specialty Neurosurgery
Date 2014 Jan 28
PMID 24460486
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

It is possible to improve neuronavigation during image-guided surgery by warping the high-quality preoperative brain images so that they correspond with the current intraoperative configuration of the brain. In this paper, the accuracy of registration results obtained using comprehensive biomechanical models is compared with the accuracy of rigid registration, the technology currently available to patients. This comparison allows investigation into whether biomechanical modeling provides good-quality image data for neuronavigation for a larger proportion of patients than rigid registration. Preoperative images for 33 neurosurgery cases were warped onto their respective intraoperative configurations using both the biomechanics-based method and rigid registration. The Hausdorff distance-based evaluation process, which measures the difference between images, was used to quantify the performance of both registration methods. A statistical test for difference in proportions was conducted to evaluate the null hypothesis that the proportion of patients for whom improved neuronavigation can be achieved is the same for rigid and biomechanics-based registration. The null hypothesis was confidently rejected (p < 10(-4)). Even the modified hypothesis that fewer than 25% of patients would benefit from the use of biomechanics-based registration was rejected at a significance level of 5% (p = 0.02). The biomechanics-based method proved particularly effective in cases demonstrating large craniotomy-induced brain deformations. The outcome of this analysis suggests that nonlinear biomechanics-based methods are beneficial to a large proportion of patients and can be considered for use in the operating theater as a possible means of improving neuronavigation and surgical outcomes.

Citing Articles

The Feasibility and Accuracy of Holographic Navigation with Laser Crosshair Simulator Registration on a Mixed-Reality Display.

Qi Z, Jin H, Wang Q, Gan Z, Xiong R, Zhang S Sensors (Basel). 2024; 24(3).

PMID: 38339612 PMC: 10857152. DOI: 10.3390/s24030896.


SlicerCBM: automatic framework for biomechanical analysis of the brain.

Safdar S, Zwick B, Yu Y, Bourantas G, Joldes G, Warfield S Int J Comput Assist Radiol Surg. 2023; 18(10):1925-1940.

PMID: 37004646 PMC: 10497672. DOI: 10.1007/s11548-023-02881-7.


Alignment of Cortical Vessels viewed through the Surgical Microscope with Preoperative Imaging to Compensate for Brain Shift.

Haouchine N, Juvekar P, Golby A, Wells 3rd W, Cotin S, Frisken S Proc SPIE Int Soc Opt Eng. 2021; 11315.

PMID: 33840881 PMC: 8035814. DOI: 10.1117/12.2547620.


Mathematical modeling and computer simulation of needle insertion into soft tissue.

Wittek A, Bourantas G, Zwick B, Joldes G, Esteban L, Miller K PLoS One. 2020; 15(12):e0242704.

PMID: 33351854 PMC: 7755224. DOI: 10.1371/journal.pone.0242704.


Biomechanical modeling and computer simulation of the brain during neurosurgery.

Miller K, Joldes G, Bourantas G, Warfield S, Hyde D, Kikinis R Int J Numer Method Biomed Eng. 2019; 35(10):e3250.

PMID: 31400252 PMC: 6785376. DOI: 10.1002/cnm.3250.


References
1.
Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin J, Pujol S . 3D Slicer as an image computing platform for the Quantitative Imaging Network. Magn Reson Imaging. 2012; 30(9):1323-41. PMC: 3466397. DOI: 10.1016/j.mri.2012.05.001. View

2.
Nakaji P, Spetzler R . Innovations in surgical approach: the marriage of technique, technology, and judgment. Clin Neurosurg. 2004; 51:177-85. View

3.
Ferrant M, Nabavi A, Macq B, Black P, Jolesz F, Kikinis R . Serial registration of intraoperative MR images of the brain. Med Image Anal. 2002; 6(4):337-59. DOI: 10.1016/s1361-8415(02)00060-9. View

4.
Joldes G, Wittek A, Miller K . Suite of finite element algorithms for accurate computation of soft tissue deformation for surgical simulation. Med Image Anal. 2009; 13(6):912-9. PMC: 2783832. DOI: 10.1016/j.media.2008.12.001. View

5.