Editor's Choice--Use of Disposable Radiation-absorbing Surgical Drapes Results in Significant Dose Reduction During EVAR Procedures

Overview
Publisher Elsevier
Date 2014 Jan 22
PMID 24445087
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: Because of the increasing number of interventional endovascular procedures with fluoroscopy and the corresponding high annual dose for interventionalists, additional dose-protecting measures are desirable. The purpose of this study was to evaluate the effect of disposable radiation-absorbing surgical drapes in reducing scatter radiation exposure for interventionalists and supporting staff during an endovascular aneurysm repair (EVAR) procedure.

Materials: This was a randomized control trial in which 36 EVAR procedures were randomized between execution with and without disposable radiation-absorbing surgical drapes (Radpad: Worldwide Innovations & Technologies, Inc., Kansas City, US, type 5511A). Dosimetric measurements were performed on the interventionalist (hand and chest) and theatre nurse (chest) with and without the use of the drapes to obtain the dose reduction and effect on the annual dose caused by the drapes.

Results: Use of disposable radiation-absorbing surgical drapes resulted in dose reductions of 49%, 55%, and 48%, respectively, measured on the hand and chest of the interventionalist and the chest of the theatre nurse.

Conclusions: The use of disposable radiation-absorbing surgical drapes significantly reduces scatter radiation exposure for both the interventionalist and the supporting staff during EVAR procedures.

Citing Articles

RAdiation Dose Attenuation using RADPAD in CATH lab for primary and secondary operators - RADAR-CATH STUDY.

Saha S, Kapoor A, Raut K, Katheria A, Khare H, Sahu A AsiaIntervention. 2024; 10(2):135-143.

PMID: 39070977 PMC: 11261659. DOI: 10.4244/AIJ-D-23-00058.


Assessing the Efficacy of RADPAD Protection Drape in Reducing Radiation Exposure to Operators in the Cardiac Catheterization Laboratory: A Systematic Review and Meta-Analysis.

Bahar A, Khanal R, Hamza M, Goru R, Shafiq A, Haider M Cureus. 2024; 16(4):e59215.

PMID: 38807800 PMC: 11132176. DOI: 10.7759/cureus.59215.


Reduction in Primary Operator Radiation Dose Exposure During Coronary Angioplasty Using Radiation Absorbing Drape.

Sharma A, Agrawal R Cureus. 2023; 15(10):e46619.

PMID: 37937037 PMC: 10626564. DOI: 10.7759/cureus.46619.


A comparison of patient dose and occupational eye dose to the operator and nursing staff during transcatheter cardiac and endovascular procedures.

Wilson-Stewart K, Fontanarosa D, Malacova E, Trapp J Sci Rep. 2023; 13(1):2391.

PMID: 36765105 PMC: 9918729. DOI: 10.1038/s41598-023-28704-y.


Minimizing scattered radiation dose in cardiac catheterization laboratory during interventional procedures using lead free drape - MILD study.

Bhat K, Guleria V, Singla M, Bohra V, Kumar J R, Bharadwaj P Indian Heart J. 2022; 74(3):201-205.

PMID: 35427629 PMC: 9243615. DOI: 10.1016/j.ihj.2022.04.001.