» Articles » PMID: 24445003

Ageing and Moisture Uptake in Polymethyl Methacrylate (PMMA) Bone Cements

Overview
Publisher Elsevier
Date 2014 Jan 22
PMID 24445003
Citations 27
Authors
Affiliations
Soon will be listed here.
Abstract

Bone cements are extensively employed in orthopaedics for joint arthroplasty, however implant failure in the form of aseptic loosening is known to occur after long-term use. The exact mechanism causing this is not well understood, however it is thought to arise from a combination of fatigue and chemical degradation resulting from the hostile in vivo environment. In this study, two commercial bone cements were aged in an isotonic fluid at physiological temperatures and changes in moisture uptake, microstructure and mechanical and fatigue properties were studied. Initial penetration of water into the cement followed Fickian diffusion and was thought to be caused by vacancies created by leaching monomer. An increase in weight of approximately 2% was experienced after 30 days ageing and was accompanied by hydrolysis of poly(methyl methacrylate) (PMMA) in the outermost layers of the cement. This molecular change and the plasticising effect of water resulted in reduced mechanical and fatigue properties over time. Cement ageing is therefore thought to be a key contributor in the long-term failure of cemented joint replacements. The results from this study have highlighted the need to develop cements capable of withstanding long-term degradation and for more accurate test methods, which fully account for physiological ageing.

Citing Articles

Effect of Orange Juice on the Properties of Heat-Polymerized and 3D-Printed Denture Materials.

Tosun B, Ozturk Z, Uysal N Polymers (Basel). 2025; 17(1.

PMID: 39795458 PMC: 11722772. DOI: 10.3390/polym17010056.


Investigating the role of temperature and moisture on the degradation of 3D-printed polymethyl methacrylate dental materials through molecular dynamics simulations.

Saini R, Vaddamanu S, Dermawan D, Mosaddad S, Heboyan A Sci Rep. 2024; 14(1):26079.

PMID: 39478155 PMC: 11526103. DOI: 10.1038/s41598-024-77736-5.


Reprogrammable, Sustainable, and 3D-Printable Cellulose Hydroplastic.

Koh J, Koh X, Chee J, Chakraborty S, Tee S, Zhang D Adv Sci (Weinh). 2024; 11(29):e2402390.

PMID: 38803059 PMC: 11304289. DOI: 10.1002/advs.202402390.


Effects of various beverages on characteristics of provisional restoration materials.

Wayakanon P, Narakaew T, Wayakanon K Clin Exp Dent Res. 2024; 10(2):e842.

PMID: 38597122 PMC: 11004904. DOI: 10.1002/cre2.842.


Radiopacity Enhancements in Polymeric Implant Biomaterials: A Comprehensive Literature Review.

Emonde C, Eggers M, Wichmann M, Hurschler C, Ettinger M, Denkena B ACS Biomater Sci Eng. 2024; 10(3):1323-1334.

PMID: 38330191 PMC: 10934286. DOI: 10.1021/acsbiomaterials.3c01667.


References
1.
Graham J, Pruitt L, Ries M, Gundiah N . Fracture and fatigue properties of acrylic bone cement: the effects of mixing method, sterilization treatment, and molecular weight. J Arthroplasty. 2000; 15(8):1028-35. DOI: 10.1054/arth.2000.8188. View

2.
Messick K, Miller M, Damron L, Race A, Clarke M, Mann K . Vacuum-mixing cement does not decrease overall porosity in cemented femoral stems: an in vitro laboratory investigation. J Bone Joint Surg Br. 2007; 89(8):1115-21. PMC: 2292250. DOI: 10.1302/0301-620X.89B8.19129. View

3.
Mazzullo S, Paolini M, Verdi C . Numerical simulation of thermal bone necrosis during cementation of femoral prostheses. J Math Biol. 1991; 29(5):475-94. DOI: 10.1007/BF00160473. View

4.
Herman J, Sowder W, Anderson D, Appel A, Hopson C . Polymethylmethacrylate-induced release of bone-resorbing factors. J Bone Joint Surg Am. 1989; 71(10):1530-41. View

5.
Lewis G, van Hooy-Corstjens C, Bhattaram A, Koole L . Influence of the radiopacifier in an acrylic bone cement on its mechanical, thermal, and physical properties: barium sulfate-containing cement versus iodine-containing cement. J Biomed Mater Res B Appl Biomater. 2005; 73(1):77-87. DOI: 10.1002/jbm.b.30176. View