» Articles » PMID: 24435222

Mobile-bearing Prosthesis and Intraoperative Gap Balancing Are Not Predictors of Superior Knee Flexion: a Prospective Randomized Study

Overview
Publisher Wiley
Date 2014 Jan 18
PMID 24435222
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Range of motion is a crucial measure of the outcome of total knee arthroplasty. Gap balancing technique and mobile-bearing prosthesis can improve postoperative range of motion. The purpose of this study was to determine the factors that are predictive of the postoperative range of motion.

Methods: A total of 94 knees with varus osteoarthritis were prospectively randomized to receive either a posterior-stabilized mobile-bearing or a posterior-stabilized fixed-bearing prosthesis. All preoperative and postoperative protocols and operative techniques were identical in the two groups. Extension and flexion joint gaps were measured using a tensor device during the operation. Multiple regression analysis was conducted to determine the best predictors of the knee flexion angle 2 years after the operation. The independent variables were type of prosthesis (mobile-bearing or fixed-bearing), difference between flexion and extension joint gaps (mm), age, gender, body mass index (BMI), preoperative and intraoperative knee flexion angles, change in posterior condylar offset, and posterior tilt of the tibial plateau.

Results: The mean difference between flexion and extension joint gaps was 0.8 ± 1.3 (mean ± SD) mm for mobile-bearing and 0.8 ± 1.9 mm for fixed-bearing prosthesis. The mean flexion angle for mobile-bearing and fixed-bearing groups was 120 ± 16° and 116 ± 20° preoperatively (n.s.), 142 ± 9° and 141 ± 12° intraoperatively (n.s.), and 129 ± 10° and 128 ± 13° at 2 years postoperatively (p = 0.773), respectively. Predictors were identified in the following three categories: (1) preoperative flexion angle, (2) intraoperative radiographic flexion angle, and (3) BMI (R = 0.603, p < 0.001).

Conclusions: Mobile-bearing prosthesis and optimal gap balancing did not result in superior postoperative flexion angle. Better preoperative and intraoperative flexion angles and lower BMI were the significant predictors for better postoperative flexion angle.

Level Of Evidence: Therapeutic study, Level I.

Citing Articles

Comparison of postoperative clinical outcomes and knee stability of cruciate-retaining total knee arthroplasty using the tibia-first gap navigation technique with a computer-aided system and measured-resection technique: A retrospective analysis of....

Iguchi M, Takahashi T, Ae R, Takeshita K J Exp Orthop. 2024; 11(3):e12084.

PMID: 38974051 PMC: 11224964. DOI: 10.1002/jeo2.12084.


No difference between mobile and fixed bearing in primary total knee arthroplasty: a meta-analysis.

Migliorini F, Maffulli N, Cuozzo F, Pilone M, Elsner K, Eschweiler J Knee Surg Sports Traumatol Arthrosc. 2022; 30(9):3138-3154.

PMID: 35861866 PMC: 9418337. DOI: 10.1007/s00167-022-07065-5.


Mobile-bearing versus fixed-bearing total knee arthroplasty: a meta-analysis of randomized controlled trials.

Hantouly A, Ahmed A, Alzobi O, Toubasi A, Salameh M, Elmhiregh A Eur J Orthop Surg Traumatol. 2021; 32(3):481-495.

PMID: 34021791 PMC: 8924090. DOI: 10.1007/s00590-021-02999-x.


[Research progress of larger flexion gap than extension gap in total knee arthroplasty].

Zhang W, Hao D Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2018; 31(5):620-623.

PMID: 29798554 PMC: 8498240. DOI: 10.7507/1002-1892.201611069.


No differences between fixed- and mobile-bearing total knee arthroplasty.

Fransen B, van Duijvenbode D, Hoozemans M, Burger B Knee Surg Sports Traumatol Arthrosc. 2016; 25(6):1757-1777.

PMID: 27324479 DOI: 10.1007/s00167-016-4195-x.


References
1.
Kim Y, Sohn K, Kim J . Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am. 2005; 87(7):1470-5. DOI: 10.2106/JBJS.D.02707. View

2.
Delport H, Banks S, De Schepper J, Bellemans J . A kinematic comparison of fixed- and mobile-bearing knee replacements. J Bone Joint Surg Br. 2006; 88(8):1016-21. DOI: 10.1302/0301-620X.88B8.17529. View

3.
Bistolfi A, Massazza G, Lee G, Deledda D, Berchialla P, Crova M . Comparison of fixed and mobile-bearing total knee arthroplasty at a mean follow-up of 116 months. J Bone Joint Surg Am. 2013; 95(12):e83. DOI: 10.2106/JBJS.L.00327. View

4.
Matsuda S, Kawahara S, Okazaki K, Tashiro Y, Iwamoto Y . Postoperative alignment and ROM affect patient satisfaction after TKA. Clin Orthop Relat Res. 2012; 471(1):127-33. PMC: 3528933. DOI: 10.1007/s11999-012-2533-y. View

5.
Koshino T, Tsuchiya K . The effect of high tibial osteotomy on osteoarthritis of the knee : Clinical and histological observations. Int Orthop. 2016; 3(1):37-45. DOI: 10.1007/BF00266324. View