» Articles » PMID: 24404009

A Numerical Study on Distributions During Cryoprotectant Loading Caused by Laminar Flow in a Microchannel

Overview
Date 2014 Jan 10
PMID 24404009
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

In this work, we conduct a computational study on the loading of cryoprotective agents into cells in preparation for cryopreservation. The advantages of microfluidics in cryopreserving cells include control of fluid flow parameters for reliable cryoprotectant loading and reproducible streamlined processing of samples. A 0.25 m long, three inlet T-junction microchannel serves as an idealized environment for this process. The flow field and concentration distribution are determined from a computational fluid dynamics study and cells are tracked as inert particles in a Lagrangian frame. These particles are not confined to streamlines but can migrate laterally due to the Segre-Sildeberg effect for particles in a shear flow. During this tracking, the local concentration field surrounding the cell is monitored. This data are used as input into the Kedem-Katchalsky equations to numerically study passive solute transport across the cell membrane. As a result of the laminar flow, each cell has a unique pathline in the flow field resulting in different residence times and a unique external concentration field along its path. However, in most previous studies, the effect of a spatially varying concentration field on the transport across the cell membrane is ignored. The dynamics of this process are investigated for a population of cells released from the inlet. Using dimensional analysis, we find a governing parameter α, which is the ratio of the time scale for membrane transport to the average residence time in the channel. For [Formula: see text], cryoprotectant loading is completed to within 5% of the target concentration for all of the cells. However, for [Formula: see text], we find the population of cells does not achieve complete loading and there is a distribution of intracellular cryoprotective agent concentration amongst the population. Further increasing α beyond a value of 2 leads to negligible cryoprotectant loading. These simulations on populations of cells may lead to improved microfluidic cryopreservation protocols where more consistent cryoprotective agent loading and freezing can be achieved, thus increasing cell survival.

Citing Articles

Enhanced inertial focusing of microparticles and cells by integrating trapezoidal microchambers in spiral microfluidic channels.

Al-Halhouli A, Albagdady A, Al-Faqheri W, Kottmeier J, Meinen S, Frey L RSC Adv. 2022; 9(33):19197-19204.

PMID: 35516901 PMC: 9064905. DOI: 10.1039/c9ra03587g.


Synergistic Development of Biochips and Cell Preservation Methodologies: A Tale of Converging Technologies.

Wang S, Elliott G Curr Stem Cell Rep. 2017; 3(1):45-53.

PMID: 28966905 PMC: 5619239. DOI: 10.1007/s40778-017-0074-8.


3D printed microfluidic mixer for point-of-care diagnosis of anemia.

Plevniak K, Campbell M, He M Annu Int Conf IEEE Eng Med Biol Soc. 2017; 2016:267-270.

PMID: 28268328 PMC: 6347025. DOI: 10.1109/EMBC.2016.7590691.


Microfluidics for cryopreservation.

Zhao G, Fu J Biotechnol Adv. 2017; 35(2):323-336.

PMID: 28153517 PMC: 6236673. DOI: 10.1016/j.biotechadv.2017.01.006.


3D printed auto-mixing chip enables rapid smartphone diagnosis of anemia.

Plevniak K, Campbell M, Myers T, Hodges A, He M Biomicrofluidics. 2016; 10(5):054113.

PMID: 27733894 PMC: 5055529. DOI: 10.1063/1.4964499.


References
1.
Chen H, Purtteman J, Heimfeld S, Folch A, Gao D . Development of a microfluidic device for determination of cell osmotic behavior and membrane transport properties. Cryobiology. 2007; 55(3):200-9. DOI: 10.1016/j.cryobiol.2007.08.001. View

2.
Hanna J, Hubel A, Lemke E . Diffusion-based extraction of DMSO from a cell suspension in a three stream, vertical microchannel. Biotechnol Bioeng. 2012; 109(9):2316-24. PMC: 6339700. DOI: 10.1002/bit.24499. View

3.
Tiersch T, Yang H, Hu E . Outlook for development of high-throughput cryopreservation for small-bodied biomedical model fishes. Comp Biochem Physiol C Toxicol Pharmacol. 2011; 155(1):49-54. DOI: 10.1016/j.cbpc.2011.08.007. View

4.
Park D, Egnatchik R, Bordelon H, Tiersch T, Monroe W . Microfluidic mixing for sperm activation and motility analysis of pearl Danio zebrafish. Theriogenology. 2012; 78(2):334-44. PMC: 3640303. DOI: 10.1016/j.theriogenology.2012.02.008. View

5.
Xu F, Moon S, Zhang X, Shao L, Song Y, Demirci U . Multi-scale heat and mass transfer modelling of cell and tissue cryopreservation. Philos Trans A Math Phys Eng Sci. 2010; 368(1912):561-83. PMC: 3263795. DOI: 10.1098/rsta.2009.0248. View