Abstract

While intraoperative three-dimensional fluoroscopy does not possess the resolution and image quality of computed tomography (CT), it may provide adequate information about screw placement to guide intra- and postoperative decision making. We compared the accuracy of intraoperative three-dimensional fluoroscopy visualization of proper screw placement with that of postoperative CT. We retrospectively reviewed spinal instrumentation procedures done using the O-arm (Medtronic, Minneapolis, MN, USA) that also had postoperative CT. All screws were assessed for placement accuracy on O-arm and CT images on a 4-point scale. In this study, 20 cases met the inclusion criteria. Thirteen breaches (11 grade 1 and 2 grade 2) were identified on O-arm images, and 14 breaches (10 grade 1, 3 grade 2, and 1 grade 3) were identified on CT. Sensitivity, specificity, and positive and negative predictive values were 93, 99, 99, and 98%, respectively. The Kappa value (0.96) suggested a very high degree of agreement between three-dimensional fluoroscopy and CT in determining accuracy of screw placement. These findings may allow less frequent use of postoperative CT scans, improving cost effectiveness in patients who require spinal instrumentation procedures and potentially decreasing the number of patients who require replacement of an inappropriately positioned screw.

Citing Articles

Accuracy of pedicle screw placement in the thoracic and lumbosacral spines using O-arm-based navigation versus conventional freehand technique.

Jing L, Wang Z, Sun Z, Zhang H, Wang J, Wang G Chin Neurosurg J. 2020; 5:6.

PMID: 32922906 PMC: 7398394. DOI: 10.1186/s41016-019-0154-y.


A learning-based method for online adjustment of C-arm Cone-beam CT source trajectories for artifact avoidance.

Thies M, Zach J, Gao C, Taylor R, Navab N, Maier A Int J Comput Assist Radiol Surg. 2020; 15(11):1787-1796.

PMID: 32840721 PMC: 7603453. DOI: 10.1007/s11548-020-02249-1.


Accuracy of a new intraoperative cone beam CT imaging technique (Artis zeego II) compared to postoperative CT scan for assessment of pedicle screws placement and breaches detection.

Cordemans V, Kaminski L, Banse X, Francq B, Cartiaux O Eur Spine J. 2017; 26(11):2906-2916.

PMID: 28528479 DOI: 10.1007/s00586-017-5139-y.


A new 3-dimensional method for measuring precision in surgical navigation and methods to optimize navigation accuracy.

Kleck C, Cullilmore I, LaFleur M, Lindley E, Rentschler M, Burger E Eur Spine J. 2015; 25(6):1764-74.

PMID: 26394858 DOI: 10.1007/s00586-015-4235-0.


Economics of image guidance and navigation in spine surgery.

Al-Khouja L, Shweikeh F, Pashman R, Johnson J, Kim T, Drazin D Surg Neurol Int. 2015; 6(Suppl 10):S323-6.

PMID: 26167370 PMC: 4496834. DOI: 10.4103/2152-7806.159381.

References
1.
Holly L, Foley K . Image guidance in spine surgery. Orthop Clin North Am. 2007; 38(3):451-61. DOI: 10.1016/j.ocl.2007.04.001. View

2.
Zausinger S, Scheder B, Uhl E, Heigl T, Morhard D, Tonn J . Intraoperative computed tomography with integrated navigation system in spinal stabilizations. Spine (Phila Pa 1976). 2009; 34(26):2919-26. DOI: 10.1097/BRS.0b013e3181b77b19. View

3.
Zhang J, Weir V, Fajardo L, Lin J, Hsiung H, Ritenour E . Dosimetric characterization of a cone-beam O-arm imaging system. J Xray Sci Technol. 2009; 17(4):305-17. DOI: 10.3233/XST-2009-0231. View

4.
Rampersaud Y, Foley K, Shen A, Williams S, Solomito M . Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976). 2000; 25(20):2637-45. DOI: 10.1097/00007632-200010150-00016. View

5.
Smith H, Welsch M, Sasso R, Vaccaro A . Comparison of radiation exposure in lumbar pedicle screw placement with fluoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging. J Spinal Cord Med. 2008; 31(5):532-7. PMC: 2607125. DOI: 10.1080/10790268.2008.11753648. View