Abstract

Purpose: The aim of the present in vivo study was to evaluate whether a difference exists between the maxilla and the mandible regarding the precision of implant placement utilizing a cone beam computed tomography (CBCT)-derived mucosa-supported stereolithographic (SLA) template.

Materials And Methods: Eighty implants (44 maxilla, 36 mandible) were placed in 18 fully edentulous jaws (10 maxillas, eight mandibles) using a mucosa-supported SLA surgical template. A voxel-based registration technique was applied to match the postoperative and preoperative CBCT scans.

Results: Vertical deviation (p = .026) at the implant hex and angular deviation (p = .0188) were significantly lower in the maxilla than in the mandible. The global linear deviation and lateral deviation at the implant hex were not significantly different. At the implant apex, the average maximum vertical deviation was within 1 mm (0.1-4.6 mm). The average maximum lateral deviation was 1.8 mm (0.9-5.5 mm) in the maxilla and 2.3 mm (0.5-5.5 mm) in the mandible when a 15-mm-long implant was placed.

Conclusions: When using CBCT-derived mucosa-supported SLA templates, clinicians should be aware of differences in the angular deviation of the implants in the mandible and maxilla. The average maximum linear deviation should be considered as a safety margin at the implant apex.

Citing Articles

Deep learning-based approach for 3D bone segmentation and prediction of missing tooth region for dental implant planning.

Al-Asali M, Alqutaibi A, Al-Sarem M, Saeed F Sci Rep. 2024; 14(1):13888.

PMID: 38880802 PMC: 11180661. DOI: 10.1038/s41598-024-64609-0.


Recent Advances in 3D Printing of Polymers for Application in Prosthodontics.

Dimitrova M, Vlahova A, Kalachev Y, Zlatev S, Kazakova R, Capodiferro S Polymers (Basel). 2024; 15(23).

PMID: 38231950 PMC: 10708542. DOI: 10.3390/polym15234525.


Accuracy of a novel modified single computed tomography scanning method for assisting dental implant placement: a retrospective observational study.

Shimizu H, Mino T, Kurosaki Y, Arakawa H, Tokumoto K, Kimura-Ono A Int J Implant Dent. 2023; 9(1):42.

PMID: 37917412 PMC: 10622383. DOI: 10.1186/s40729-023-00509-8.


Accuracy Analysis of Computer-Assisted and Guided Dental Implantology by Comparing 3D Planning Data and Actual Implant Placement in a Mandibular Training Model: A Monocentric Comparison between Dental Students and Trained Implantologists.

Ebeling M, Sakkas A, Schramm A, Wilde F, Scheurer M, Winter K J Pers Med. 2023; 13(7).

PMID: 37511650 PMC: 10381824. DOI: 10.3390/jpm13071037.


Additive Manufactured Polymers in Dentistry, Current State-of-the-Art and Future Perspectives-A Review.

Tigmeanu C, Ardelean L, Rusu L, Negrutiu M Polymers (Basel). 2022; 14(17).

PMID: 36080732 PMC: 9460687. DOI: 10.3390/polym14173658.