Three-dimensional Personalized Dosimetry for Re Liver Selective Internal Radiation Therapy Based on Quantitative Post-treatment SPECT Studies
Overview
Nuclear Medicine
Radiology
Authors
Affiliations
We demonstrate that accurate patient-specific distributions of microspheres labeled with Re and resulting absorbed doses can be obtained from single-photon emission computed tomography (SPECT) studies performed after Re selective internal radiation therapy when accurate correction methods are employed in image reconstruction. Our quantitative image reconstruction algorithm includes corrections for attenuation, resolution degradations and scatter as well as a window-based compensation for contamination. The procedure has been validated using four phantom experiments containing an 18 ml cylindrical source (82-93 MBq of Re activity) simulating a liver tumor. In addition, we applied our approach to post-therapy SPECT studies of ten patients with progressive primary or metastatic liver carcinomas. Our quantitative algorithm accurately (within 9%) recovered Re activity from four phantom experiments. In addition, for two patients that received three scans, deviations remained consistent between the measured and the reconstructed activities that were determined from studies with differing severity of the dead-time effect. The analysis of absorbed doses for patient studies allowed us to hypothesize that D90 (the minimum dose received by 90% of the tumor volume) may be a reliable metric relating therapy outcomes to the calculated doses. Among several considered metrics, only D90 showed statistically significant correlation with the overall survival.
De La Vega J, Esquinas P, Rodriguez-Rodriguez C, Bokharaei M, Moskalev I, Liu D Theranostics. 2019; 9(3):868-883.
PMID: 30809314 PMC: 6376476. DOI: 10.7150/thno.29381.
Esquinas P, Shinto A, Kamaleshwaran K, Joseph J, Celler A EJNMMI Phys. 2018; 5(1):30.
PMID: 30523435 PMC: 6283804. DOI: 10.1186/s40658-018-0227-6.
Determination of gamma camera calibration factors for quantitation of therapeutic radioisotopes.
Zhao W, Esquinas P, Hou X, Uribe C, Gonzalez M, Beauregard J EJNMMI Phys. 2018; 5(1):8.
PMID: 29717385 PMC: 5930296. DOI: 10.1186/s40658-018-0208-9.
Accuracy of Lu activity quantification in SPECT imaging: a phantom study.
Uribe C, Esquinas P, Tanguay J, Gonzalez M, Gaudin E, Beauregard J EJNMMI Phys. 2017; 4(1):2.
PMID: 28063068 PMC: 5218957. DOI: 10.1186/s40658-016-0170-3.
Nowicki M, Cwikla J, Sankowski A, Shcherbinin S, Grimmes J, Celler A Med Sci Monit. 2014; 20:1353-62.
PMID: 25086245 PMC: 4136939. DOI: 10.12659/MSM.890480.