» Articles » PMID: 24328359

Resolving Isotopic Fine Structure to Detect and Quantify Natural Abundance- and Hydrogen/deuterium Exchange-derived Isotopomers

Overview
Journal Anal Chem
Specialty Chemistry
Date 2013 Dec 17
PMID 24328359
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Hydrogen/deuterium exchange (HDX) mass spectrometry (MS) is used for analyzing protein dynamics, protein folding/unfolding, and molecular interactions. Until this study, HDX MS experiments employed mass spectral resolving powers that afforded only one peak per nominal mass in a given peptide's isotope distribution, and HDX MS data analysis methods were developed accordingly. A level of complexity that is inherent to HDX MS remained unaddressed, namely, various combinations of natural abundance heavy isotopes and exchanged deuterium shared the same nominal mass and overlapped at previous resolving powers. For example, an A + 2 peak is comprised of (among other isotopomers) a two-(2)H-exchanged/zero-(13)C isotopomer, a one-(2)H-exchanged/one-(13)C isotopomer, and a zero-(2)H-exchanged/two-(13)C isotopomer. Notably, such isotopomers differ slightly in mass as a result of the ∼3 mDa mass defect between (2)H and (13)C atoms. Previous HDX MS methods did not resolve these isotopomers, requiring a natural-abundance-only (before HDX or "time zero") spectrum and data processing to remove its contribution. It is demonstrated here that high-resolution mass spectrometry can be used to detect isotopic fine structure, such as in the A + 2 profile example above, deconvolving the isotopomer species resulting from deuterium incorporation. Resolving isotopic fine structure during HDX MS therefore permits direct monitoring of HDX, which can be calculated as the sum of the fractional peak magnitudes of the deuterium-exchanged isotopomers. This obviates both the need for a time zero spectrum as well as data processing to account for natural abundance heavy isotopes, saving instrument and analysis time.

Citing Articles

Advances in Hydrogen/Deuterium Exchange Mass Spectrometry and the Pursuit of Challenging Biological Systems.

James E, Murphree T, Vorauer C, Engen J, Guttman M Chem Rev. 2021; 122(8):7562-7623.

PMID: 34493042 PMC: 9053315. DOI: 10.1021/acs.chemrev.1c00279.


Routine Absorption Mode FTMS Data Display with an Ethoxylated Anionic Detergent as a Dual-Role (Mass and Phase) Calibrant.

Hu P, Cole D J Am Soc Mass Spectrom. 2018; 30(3):468-475.

PMID: 30456597 DOI: 10.1007/s13361-018-2099-3.


Parsing disease-relevant protein modifications from epiphenomena: perspective on the structural basis of SOD1-mediated ALS.

Schmitt N, Agar J J Mass Spectrom. 2017; 52(7):480-491.

PMID: 28558143 PMC: 6002871. DOI: 10.1002/jms.3953.


QUDeX-MS: hydrogen/deuterium exchange calculation for mass spectra with resolved isotopic fine structure.

Salisbury J, Liu Q, Agar J BMC Bioinformatics. 2014; 15:403.

PMID: 25495703 PMC: 4274694. DOI: 10.1186/s12859-014-0403-1.


Applications of hydrogen/deuterium exchange MS from 2012 to 2014.

Pirrone G, Iacob R, Engen J Anal Chem. 2014; 87(1):99-118.

PMID: 25398026 PMC: 4287169. DOI: 10.1021/ac5040242.


References
1.
Nikamanon P, Pun E, Chou W, Koter M, Gershon P . "TOF2H": a precision toolbox for rapid, high density/high coverage hydrogen-deuterium exchange mass spectrometry via an LC-MALDI approach, covering the data pipeline from spectral acquisition to HDX rate analysis. BMC Bioinformatics. 2008; 9:387. PMC: 2561049. DOI: 10.1186/1471-2105-9-387. View

2.
Qi Y, Thompson C, Van Orden S, OConnor P . Phase correction of Fourier transform ion cyclotron resonance mass spectra using MatLab. J Am Soc Mass Spectrom. 2011; 22(1):138-47. DOI: 10.1007/s13361-010-0006-7. View

3.
Zhong W, Yang J . Determination of a trace level enol impurity by on-line hydrogen/deuterium exchange combined with ultra-high mass resolution and ultra-high mass accuracy Fourier transform ion cyclotron resonance mass spectrometry. Rapid Commun Mass Spectrom. 2009; 23(19):3255-8. DOI: 10.1002/rcm.4229. View

4.
Kazazic S, Zhang H, Schaub T, Emmett M, Hendrickson C, Blakney G . Automated data reduction for hydrogen/deuterium exchange experiments, enabled by high-resolution Fourier transform ion cyclotron resonance mass spectrometry. J Am Soc Mass Spectrom. 2010; 21(4):550-8. PMC: 2901854. DOI: 10.1016/j.jasms.2009.12.016. View

5.
Abzalimov R, Kaplan D, Easterling M, Kaltashov I . Protein conformations can be probed in top-down HDX MS experiments utilizing electron transfer dissociation of protein ions without hydrogen scrambling. J Am Soc Mass Spectrom. 2009; 20(8):1514-7. PMC: 2725517. DOI: 10.1016/j.jasms.2009.04.006. View