The continuous autotransfusion system has been widely used in surgical operations. It is known that if oil is added to blood, and this mixture is then processed by an autotransfusion device, the added oil is removed and reinfusion of fat is prevented by the device. However, there is no detailed report on the influence of the particular washing program selected on the levels of blood components including blood fat after continuous autotransfusion using such a system. Fresh bovine blood samples were processed by a commercial continuous autotransfusion device using the "emergency," "quality," and "high-quality" programs, applied in random order. Complete blood count (CBC) and serum chemistry were analyzed to determine how the blood processing performance of the device changes with the washing program applied. There was no significant difference in the CBC results obtained with the three washing programs. Although all of the blood lipids in the processed blood were decreased compared to those in the blood before processing, the levels of triglyceride, phospholipid, and total cholesterol after processing via the emergency program were significantly higher than those present after processing via the quality and high-quality programs. Although the continuous autotransfusion device provided consistent hematocrit quality, the levels of some blood lipid components showed significant differences among the washing programs.

Citing Articles

A novel autotransfusion device saving erythrocytes and platelets used in a 72 h survival swine model of surgically induced controlled blood loss.

Schreiber K, Decouture B, Lafragette A, Chollet S, Bruneau M, Nicollet M PLoS One. 2022; 17(3):e0260855.

PMID: 35324911 PMC: 8947136. DOI: 10.1371/journal.pone.0260855.


Tangential flow filtration facilitated washing of human red blood cells: A proof-of-concept study.

Lu S, Allyn M, Weigand M, Chalmers J, Palmer A Vox Sang. 2022; 117(6):803-811.

PMID: 35262216 PMC: 9203871. DOI: 10.1111/vox.13259.


Traditional and emerging technologies for washing and volume reducing blood products.

Lu M, Lezzar D, Voros E, Shevkoplyas S J Blood Med. 2019; 10:37-46.

PMID: 30655711 PMC: 6322496. DOI: 10.2147/JBM.S166316.

References
1.
Shulman G . Quality of processed blood for autotransfusion. J Extra Corpor Technol. 2000; 32(1):11-9. View

2.
Booke M, Fobker M, Fingerhut D, Storm M, Mortlemans Y, Van Aken H . Fat elimination during intraoperative autotransfusion: an in vitro investigation. Anesth Analg. 1997; 85(5):959-62. DOI: 10.1097/00000539-199711000-00002. View

3.
Booke M, Van Aken H, Storm M, Fritzsche F, Wirtz S, Hinder F . Fat elimination from autologous blood. Anesth Analg. 2001; 92(2):341-3. DOI: 10.1097/00000539-200102000-00011. View

4.
Walpoth B, Eggensperger N, Neidhart P, Lanz M, Zehnder R, Spaeth P . Qualitative assessment of blood washing with the continuous autologous transfusion system (CATS). Int J Artif Organs. 1997; 20(4):234-9. View

5.
Ramirez G, Romero A, Garcia-Vallejo J, Munoz M . Detection and removal of fat particles from postoperative salvaged blood in orthopedic surgery. Transfusion. 2002; 42(1):66-75. DOI: 10.1046/j.1537-2995.2002.00005.x. View