» Articles » PMID: 24284353

Suitability of Optical, Physical and Chemical Measurements for Detection of Changes in Bacterial Drinking Water Quality

Overview
Publisher MDPI
Date 2013 Nov 29
PMID 24284353
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

In this study, different optical, physical and chemical measurements were tested for their capacity to detect changes in water quality. The tests included UV-absorbance at 254 nm, absorbance at 420 nm, turbidity, particle counting, temperature, pH, electric conductivity (EC), free chlorine concentration and ATP concentration measurements. Special emphasis was given to investigating the potential for measurement tools to detect changes in bacterial concentrations in drinking water. Bacterial colony counts (CFU) and total bacterial cell counts (TBC) were used as reference methods for assessing the bacterial water quality. The study consists of a series of laboratory scale experiments: monitoring of regrowth of Pseudomonas fluorescens, estimation of the detection limits for optical measurements using Escherichia coli dilutions, verification of the relationships by analysing grab water samples from various distribution systems and utilisation of the measurements in the case of an accidentally contaminated distribution network. We found significant correlations between the tested measurements and the bacterial water quality. As the bacterial contamination of water often co-occurs with the intrusion of matrixes containing mainly non-bacterial components, the tested measurement tools can be considered to have the potential to rapidly detect any major changes in drinking water quality.

Citing Articles

Surface Water Intrusion, Land Use Impacts, and Bacterial Community Composition in Shallow Groundwater Wells Supplying Potable Water in Sparsely Populated Areas of a Boreal Region.

Lyons K, Hokajarvi A, Ikonen J, Kauppinen A, Miettinen I, Pitkanen T Microbiol Spectr. 2021; 9(3):e0017921.

PMID: 34730413 PMC: 8567237. DOI: 10.1128/Spectrum.00179-21.


Stagnation leads to short-term fluctuations in the effluent water quality of biofilters: A problem for greywater reuse?.

Hess A, Baum C, Schiessl K, Besmer M, Hammes F, Morgenroth E Water Res X. 2021; 13:100120.

PMID: 34647001 PMC: 8495163. DOI: 10.1016/j.wroa.2021.100120.


Application of Biosensors for Detection of Pathogenic Food Bacteria: A Review.

Ali A, Altemimi A, Alhelfi N, Ibrahim S Biosensors (Basel). 2020; 10(6).

PMID: 32486225 PMC: 7344754. DOI: 10.3390/bios10060058.

References
1.
Pronk M, Goldscheider N, Zopfi J . Particle-size distribution as indicator for fecal bacteria contamination of drinking water from karst springs. Environ Sci Technol. 2008; 41(24):8400-5. DOI: 10.1021/es071976f. View

2.
Vital M, Dignum M, Magic-Knezev A, Ross P, Rietveld L, Hammes F . Flow cytometry and adenosine tri-phosphate analysis: alternative possibilities to evaluate major bacteriological changes in drinking water treatment and distribution systems. Water Res. 2012; 46(15):4665-76. DOI: 10.1016/j.watres.2012.06.010. View

3.
van den Broeke J, Ross P, van der Helm A, Baars E, Rietveld L . Use of on-line UV/Vis-spectrometry in the measurement of dissolved ozone and AOC concentrations in drinking water treatment. Water Sci Technol. 2008; 57(8):1169-75. DOI: 10.2166/wst.2008.137. View

4.
Reynolds D, Fricker C . Application of laser scanning for the rapid and automated detection of bacteria in water samples. J Appl Microbiol. 1999; 86(5):785-95. DOI: 10.1046/j.1365-2672.1999.00721.x. View

5.
Lehtola M, Pitkanen T, Miebach L, Miettinen I . Survival of Campylobacter jejuni in potable water biofilms: a comparative study with different detection methods. Water Sci Technol. 2006; 54(3):57-61. DOI: 10.2166/wst.2006.448. View