Direct Determination of Urinary Creatinine by Reactive-thermal Desorption-extractive Electrospray-ion Mobility-tandem Mass Spectrometry
Affiliations
A direct, ambient ionization method has been developed for the determination of creatinine in urine that combines derivatization and thermal desorption with extractive electrospray ionization and ion mobility-mass spectrometry. The volatility of creatinine was enhanced by a rapid on-probe aqueous acylation reaction, using a custom-made thermal desorption probe, allowing thermal desorption and ionization of the monoacylated derivative. The monoacyl creatinine [M + H](+) ion (m/z 156) was subjected to mass-to-charge selection and collision induced dissociation to remove the acyl group, generating the protonated creatinine [M + H](+) product ion at m/z 114 before an ion mobility separation was applied to reduce chemical noise. Stable isotope dilution using creatinine-d3 as internal standard was used for quantitative measurements. The direct on-probe derivatization allows high sample throughput with a typical cycle time of 1 min per sample. The method shows good linearity (R(2) = 0.986) and repeatability (%RSD 8-10%) in the range of 0.25-2.0 mg/mL. The creatinine concentrations in diluted urine samples from a healthy individual were determined to contain a mean concentration of 1.44 mg/mL creatinine with a precision (%RSD) of 9.9%. The reactive ambient ionization approach demonstrated here has potential for the determination of involatile analytes in urine and other biofluids.
Trend in creatinine determining methods: Conventional methods to molecular-based methods.
Narimani R, Esmaeili M, Rasta S, Khosroshahi H, Mobed A Anal Sci Adv. 2024; 2(5-6):308-325.
PMID: 38716155 PMC: 10989614. DOI: 10.1002/ansa.202000074.
Transforming presumptive forensic testing: identification and age estimation of human bodily fluids.
Rankin-Turner S, Turner M, Kelly P, King R, Reynolds J Chem Sci. 2019; 10(4):1064-1069.
PMID: 30774902 PMC: 6346410. DOI: 10.1039/c8sc04133d.
Reactive Laser Ablation Electrospray Ionization Time-Resolved Mass Spectrometry of Click Reactions.
van Geenen F, Franssen M, Zuilhof H, Nielen M Anal Chem. 2018; 90(17):10409-10416.
PMID: 30063331 PMC: 6127799. DOI: 10.1021/acs.analchem.8b02290.
Perez-Hurtado P, Palmer E, Owen T, Aldcroft C, Allen M, Jones J Rapid Commun Mass Spectrom. 2017; 31(22):1947-1956.
PMID: 28857369 PMC: 5656932. DOI: 10.1002/rcm.7975.
Huang K, Li M, Li H, Li M, Jiang Y, Fang X Sci Rep. 2016; 6:19283.
PMID: 26759071 PMC: 4725369. DOI: 10.1038/srep19283.