Validation of the Fitbit One Activity Monitor Device During Treadmill Walking

Overview
Journal J Sci Med Sport
Specialty Orthopedics
Date 2013 Nov 26
PMID 24268570
Citations 116
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: In order to quantify the effects of physical activity such as walking on chronic disease, accurate measurement of physical activity is needed. The objective of this study was to determine the validity and reliability of a new activity monitor, the Fitbit One, in a population of healthy adults.

Design: Cross-sectional study.

Methods: Thirty healthy adults ambulated at 5 different speeds (0.90, 1.12, 1.33, 1.54, 1.78 m/s) on a treadmill while wearing three Fitbit One activity monitors (two on the hips and one in the pocket). The order of each speed condition was randomized. Fitbit One step count output was compared to observer counts and distance output was compared to the calibrated treadmill output. Two-way repeated measures ANOVA, concordance correlation coefficients, and Bland and Altman plots were used to assess validity and intra-class correlation coefficients (ICC) were used to assess reliability.

Results: No significant differences were noted between Fitbit One step count outputs and observer counts, and concordance was substantial (0.97-1.00). Inter-device reliability of the step count was high for all walking speeds (ICC ≥ 0.95). Percent relative error was less than 1.3%. The distance output of the Fitbit One activity monitors was significantly different from the criterion values for each monitor at all speeds (P<0.001) and exhibited poor concordance (0.0-0.05). Inter-device reliability was excellent for all treadmill speeds (ICC ≥ 0.90). Percent relative error was high (up to 39.6%).

Conclusions: The Fitbit One activity monitors are valid and reliable devices for measuring step counts in healthy young adults. The distance output of the monitors is inaccurate and should be noted with caution.

Citing Articles

A wearable alcohol biosensor: Exploring the accuracy of transdermal drinking detection.

Fairbairn C, Han J, Caumiant E, Benjamin A, Bosch N Drug Alcohol Depend. 2024; 266:112519.

PMID: 39705818 PMC: 11787854. DOI: 10.1016/j.drugalcdep.2024.112519.


Validation and interdevice reliability of a behavior monitoring collar to measure rumination, feeding activity, and idle time of lactating dairy cows.

Lovatti J, Dijkinga K, Aires J, Garrido L, Costa J, Daros R JDS Commun. 2024; 5(6):602-607.

PMID: 39650024 PMC: 11624420. DOI: 10.3168/jdsc.2023-0467.


Actívatexto: Feasibility and Acceptability of a Mobile Intervention That Promotes Smoking Cessation and Physical Activity among Latinos.

Lara D, Alaniz-Cantu E, Siddalingaiaha S, Oliveira I, Chavez-Iniguez A, DeJesus E Cancer Res Commun. 2024; 4(4):1016-1023.

PMID: 38592449 PMC: 11000686. DOI: 10.1158/2767-9764.CRC-23-0519.


Temporal Interactions between Maintenance of Cerebral Cortex Thickness and Physical Activity from an Individual Person Micro-Longitudinal Perspective and Implications for Precision Medicine.

Wall J, Xie H, Wang X J Pers Med. 2024; 14(2).

PMID: 38392561 PMC: 10890462. DOI: 10.3390/jpm14020127.


Incentivised physical activity intervention promoting daily steps among university employees in the workplace through a team-based competition.

Safi A, Deb S, Kelly A, Cole M, Walker N, Zariwala M Front Public Health. 2024; 11:1121936.

PMID: 38328536 PMC: 10848798. DOI: 10.3389/fpubh.2023.1121936.