Simulated Ion Trajectory and Induced Signal in Ion Cyclotron Resonance Ion Traps. Effect of Ion Initial Axial Position on Ion Coherence, Induced Signal, and Radial or Z Ejection in a Cubic Trap
Overview
Authors
Affiliations
The effects of ion initial axial position on coherence of ion motion, induced ion cyclotron resonance (ICR) signal. and radial and z ejection have been evaluated by numerical simulation for a cubic Fourier transform-ion cyclotron resonance ion trap. For a given initial ion cyclotron phase and radius, ions of different initial z position are shown to be excited to significantly different ion cyclotron radii (and ultimately radially ejected at significantly different excitation amplitude-duration products). Ion initial z displacement from the trap midplane affects observed ICR signal magnitude in two ways: (1) for the same postexcitation cyclotron radius, an ion with larger initial z displacement induces a smaller ICR signal and (2) an ion with larger initial z displacement is excited to a smaller cyclotron radius. We also evaluate the induced ICR signal as a function of excitation amplitude-duration product for spatially uniform or Gaussian ion initial z distributions. In general, if the excitation waveform contains components at frequency, 2 ωz or (ω+ + 2 ωz, in which ωz is the axial C"trapping") oscillation frequency, then ejection occurs axially. However, the resulting excitation amplitude-duration product for such axial ejection is significantly higher (factor of, ∼ 4) than that required for radial ejection (at ω+) for ions of small initial radius. The present results offer the first explanation of how, even if the ion is initially at rest on the z axis (i.e., zero excitation electric field amplitude on the z axis), z ejection (axial ejection) may nevertheless occur if the excitation waveform contains frequency components at ω+ + 2ωz and/or 2w z Namely, our simulations reveal that off-resonant excitation pushes ions away from the z axis, after which the ions are exposed to z excitation and eventual z ejection.
High-resolution ion isolation with the ion cyclotron resonance capacitively coupled open cell.
OConnor P, McLafferty F J Am Soc Mass Spectrom. 2013; 6(6):533-5.
PMID: 24214309 DOI: 10.1016/1044-0305(95)00232-3.
Fourier transform ion cyclotron resonance detection of multiphoton ionization spectroscopy.
Shincor S, Han S, Kim B J Am Soc Mass Spectrom. 2013; 7(10):1018-25.
PMID: 24202882 DOI: 10.1016/1044-0305(96)00050-5.
Vladimirov G, Hendrickson C, Blakney G, Marshall A, Heeren R, N Nikolaev E J Am Soc Mass Spectrom. 2011; 23(2):375-84.
PMID: 22033889 DOI: 10.1007/s13361-011-0268-8.
Rich M, Simet I, Coon S, Hanson C J Am Soc Mass Spectrom. 2000; 11(12):1118-24.
PMID: 11118119 DOI: 10.1016/S1044-0305(00)00184-7.