» Articles » PMID: 24188807

A Rabbit Osteomyelitis Model for the Longitudinal Assessment of Early Post-operative Implant Infections

Overview
Publisher Biomed Central
Specialty Orthopedics
Date 2013 Nov 6
PMID 24188807
Citations 26
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Implant infection is one of the most severe complications within the field of orthopaedic surgery, associated with an enormous burden for the healthcare system. During the last decades, attempts have been made to lower the incidence of implant-related infections. In the case of cemented prostheses, the use of antibiotic-containing bone cement can be effective. However, in the case of non-cemented prostheses, osteosynthesis and spinal surgery, local antibacterial prophylaxis is not a standard procedure. For the development of implant coatings with antibacterial properties, there is a need for a reliable animal model to evaluate the preventive capacity of such coatings during a specific period of time. Existing animal models generally present a limited follow-up, with a limited number of outcome parameters and relatively large animal numbers in multiple groups.

Methods: To represent an early post-operative implant infection, we established an acute tibial intramedullary nail infection model in rabbits by contamination of the tibial nail with 3.8 × 10⁵ colony forming units of Staphylococcus aureus. Clinical, haematological and radiological parameters for infection were weekly assessed during a 6-week follow-up with post-mortem bacteriological and histological analyses.

Results: S. aureus implant infection was confirmed by the above parameters. A saline control group did not develop osteomyelitis. By combining the clinical, haematological, radiological, bacteriological and histological data collected during the experimental follow-up, we were able to differentiate between the control and the infected condition and assess the severity of the infection at sequential timepoints in a parameter-dependent fashion.

Conclusion: We herein present an acute early post-operative rabbit implant infection model which, in contrast to previously published models, combines improved in-time insight into the development of an implant osteomyelitis with a relatively low amount of animals.

Citing Articles

Prosthetic Joint Infection Research Models in NZW Rabbits: Opportunities for Standardization-A Systematic Review.

van Agtmaal J, van Hoogstraten S, Arts J J Funct Biomater. 2024; 15(10).

PMID: 39452605 PMC: 11508679. DOI: 10.3390/jfb15100307.


The clinical significance of inflammatory biomarkers, IL6 cytokine, and systemic immune inflammatory index in rabbit model of acute and chronic Methicillin-resistant Staphylococcus epidermidis-induced osteomyelitis.

Ancuta D, Lovati A, Coman C PLoS One. 2024; 19(8):e0309145.

PMID: 39208074 PMC: 11361425. DOI: 10.1371/journal.pone.0309145.


Establishment of a mandible defect model in rabbits infected with multiple bacteria and bioinformatics analysis.

Zhao Y, Su J, Xu C, Li Y, Hu T, Li Y Front Bioeng Biotechnol. 2024; 12:1350024.

PMID: 38282893 PMC: 10811100. DOI: 10.3389/fbioe.2024.1350024.


Choosing the right animal model for osteomyelitis research: Considerations and challenges.

Huang S, Wen J, Zhang Y, Bai X, Cui Z J Orthop Translat. 2023; 43:47-65.

PMID: 38094261 PMC: 10716383. DOI: 10.1016/j.jot.2023.10.001.


Prevention of Implant-Associated Infections Caused by Antibiotic-Resistant Bacteria through Biofunctionalization of Additively Manufactured Porous Titanium.

van Hengel I, Dijk B, Modaresifar K, Hooning van Duyvenbode J, Nurmohamed F, Leeflang M J Funct Biomater. 2023; 14(10).

PMID: 37888185 PMC: 10607138. DOI: 10.3390/jfb14100520.


References
1.
Andriole V, Nagel D, Southwick W . Chronic staphylococcal osteomyelitis: an experimental model. Yale J Biol Med. 1974; 47(1):33-9. PMC: 2595166. View

2.
Zimmerli W, Lew P, Waldvogel F . Pathogenesis of foreign body infection. Evidence for a local granulocyte defect. J Clin Invest. 1984; 73(4):1191-200. PMC: 425133. DOI: 10.1172/JCI111305. View

3.
Montanaro L, Speziale P, Campoccia D, Ravaioli S, Cangini I, Pietrocola G . Scenery of Staphylococcus implant infections in orthopedics. Future Microbiol. 2011; 6(11):1329-49. DOI: 10.2217/fmb.11.117. View

4.
Jacqueline C, Amador G, Caillon J, Le Mabecque V, Batard E, Miegeville A . Efficacy of the new cephalosporin ceftaroline in the treatment of experimental methicillin-resistant Staphylococcus aureus acute osteomyelitis. J Antimicrob Chemother. 2010; 65(8):1749-52. DOI: 10.1093/jac/dkq193. View

5.
An Y, Bradley J, Powers D, Friedman R . The prevention of prosthetic infection using a cross-linked albumin coating in a rabbit model. J Bone Joint Surg Br. 1997; 79(5):816-9. DOI: 10.1302/0301-620x.79b5.7228. View